18 - 21
7 Technical
data
7-1 Specification
Voltage & frequency range available
110VAC 50/60 Hz
220 VAC 50 / 60 Hz
Electrical specification for
“NC - COM - NO” Port
6A @ 250 VAC
10 A @ 120 VAC
6A @ 30 VDC
Rated power output ( W )
80W for YET-A1 Model
100W for YET-A2 Model
Permissible operating viscosity ( cSt )
30 cSt ~ 250 cSt
Discharge rate
100 (ml/min)
Max. discharge pressure
7
±
1 (bar) for YET-A1 Model
15
±
1 (bar) for YET-A2 Model
Interminent time (minute)
1 ~ 999
dia of elbow joint. ( mm )
∮
4 or
∮
6
Dimension ( mm )
227 (W)
×
168 (D)
×
300 (H)
Oiltank capacity
3 ( L)
Operating temperature
0~50 (
℃
)
Fuse at power supply
1.2A for YET-A1 model, 220V AC
1.4A for YET-A2 model, 220V AC
Operating range for pressure switch ( bar
)
10 ~ 12
7-2 Electrical Drawing
If you meet any electrical fault, we strongly suggest you to sent the lubricator back to
the
iSH
AN
-
customer service workshops. We will changing a new PC board with same
function or updated function instead of the old one in reasonable price. The following
diagram are only a basic reference of the controller which support you to understand the
fault by yourself.