1
5.10 Adjusting the spring force
The spring is not tensioned when delivered. A primary
tension of at least 10 rotations is required for the operation.
The adjustment will be tested during the teach-in run. The
teach-in run will be aborted if the spring force is too low. A
new teach-in run must be carried out if the spring has been
readjusted.
1.
Refer to the table to find the required rotations for the
spring adjustment and adjust the spring force.
Selection EN class
Door panel width in mm 850
950
1100
EN class
EN 2 EN 3
EN 4
min. closing torque in
case of 2°
13 Nm 18 Nm
26 Nm
Rotations for the spring
adjustment
10
14
16
The table shows approximate values. You must
therefore test and correct, if necessary, the closing
torque at 2° in accordance with EN 1154. In case of
lintel depths larger than 225 mm, you must also check
the minimum closing torque between 88° – 92°.
5 mm
1
5.11 Adjusting the closing speed in an deenergized state
1.
Adjust the closing speed on the potenziometer.
The speed must be adjusted. If the door closes in less
than 3 seconds, it will lead to the error message 73
(braking circuit test).
5
1
2.5 mm
5.13 Adjusting the end stop on the slide channel
The end stop must be adjusted so that the set opening angle
cannot be exceeded when manually pushed.
1.
Turn the program switch to the PERMANENT OPEN
position.
Ź
The door will open to the adjusted opening width.
2.
Move the buffer and the end stop to 5 mm to the
sliding piece.
3.
Tighten the end stop.
We recommend the use of a door stop.
In case a normal arm assembly is used, you must use
a door stopper.
5.12 Commissioning the drive unit
1. Commissioning the drive unit. See commissioning on page 21