Parameter/display
Value range
Unit
Factory
setting
= Bold
Explanation
Configuration of the
interface COM1
(upright connector)
0 – 1
0
Not applicable
1
Not applicable
Opening dampening
when opened
manually
5 – 40
10°
In this case, enter the angle after which the door is braked
when manually opened.
The entered value counts backward from the set opening
angle.
Example: Opening angle:
90°
Parameter
bc:
12°
=> opening dampening starts at 78°
Door thickness
0 – 99
0...
35
...99
mm
The door thickness affects the measured door opening angle.
If a more accurate resolution is required, you can enter the
actual door width.
Shutdown drive
function effective
direction (4,4a)
0 – 1
0
Normally closed contact
In case of a normally closed contact, the drive function will be
shut down. This effective direction must be used for door lock
switches which are equipped with a changeover contact or
normally closed contact.
1
Normally open contact
In case of a normally open contact, the drive function will be
shut down. This effective direction must be used for door lock
switches which are equipped with a normally open contact.
Night/bank
effective direction
0 – 1
0
Normally open contact
The night/bank function will be triggered in case of a normally
open contact. This effective direction is preferred for a key
switch button or access control.
1
Normally closed contact
The night/bank function will be triggered in case of a normally
closed contact.
This effective direction is often used for the connection to a
smoke went and heat exhaust system or building management
system in order to activate doors with a normally closed
contact.
Triggering the
hold-open system
by disengaging the
door panel
0 – 1
1
Function switched on
If the drive is operated as a hold-open system, the manual
triggering can be carrried out via the manual closing of the
door panel by 10° (+/– 2°) from the taught hold-open time. A
manual release button is not required.
0
Function switched off
If the drive is operated as a hold-open system, a manual
release button will be required for the manual activation.
Castor angle for
2-panel doors
0 – 30
0...
30°
Here you can adjust the angle that the active panel has to
travel before the inactive panel begins to open.
Clearance between
hinges
+ 5 – – 5
3
The clearance between hinges is crucial for the calculated
door angle. It may only have a small effect but it can be
adjusted in extreme cases to increase the accuracy.
The basic setting of the parameter HS is 3, for 30 mm.
In case of center-pivoted doors, the setting must be changed
to the negative. A teach-in run is then required as the system
creates an angle table as a function of the set parameters.
DOO
R
P
A
RA
M
E
T
E
R