isel
Gantry and Flat-Bed Machines
Page 10
6.1.2
Assignment of the axes of motion
With reference to the operating position, the axes of motion are assigned as follows:
-
With flat-bed machines:
X axis = transversal axis (+X to right; -X to the left)
Y axis = longitudinal axis (+Y away from the operator; -Y towards the operator)
Z axis = vertical axis (+Z upwards; -Z downwards)
-
With gantry machines:
X axis = transversal axis (+X to right; -X to the left)
Y axis = longitudinal axis (+Y towards the operator; -Y away from the operator)
Z axis = vertical axis (+Z upwards; -Z downwards)
6.1.3
Reference point and home position
The reference point of the machine (machine zero)
and the home position are specified by default as the top (Z)
left (X) rear (Y) corner by default.
The reference point is defined by way of hardware limit
switches; the home position is reported to the control system by
way of an electromagnetic switching contact.
The signalling magnet is fixed on the panelling; the reading
contact on the Z axis recognises the position by proximity when
it detects the magnet.
6.1.4
Clamping the workpiece
When setting up the machine, use only suitable, safe
clamping tools (see "Accessories").
Always ensure that the workpieces are clamped securely.