![ISC GasBadge Plus 3.0 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/isc/gasbadge-plus-3-0/gasbadge-plus-3-0_manual_2092319034.webp)
34
INDUSTRIAL SCIENTIFIC
Revision 5 (p/n: 17120932)
well as a printer and a PC.
Cal Plus
Calibration Station
The communications with the instruments are supported using IrDA through the
instrument’s infrared communications port. Using this communications port, the
calibration station performs bump tests and calibrations of the instrument. The Cal
Plus saves the test results and can send the results to a serial printer. The
PC-to-Calibration Station communications are done via USB. The printer is
connected to the calibration station through an RS232 connection.
For more information on the Cal Plus calibration station, please contact your local
Industrial Scientific sales office or visit our web site at
www.indsci.com
.
DS2 Docking Station (Optional Accessory)
The DS2 Docking Station™ provides the ultimate flexibility for managing gas
monitors wherever they are used. Ethernet connectivity enables the linking of up to
700 stand-alone Instrument Docking Stations (IDSs) from remote locations
anywhere in a facility and relay the data back to one central database for total
instrument management. A graphical user interface tool allows an administrator to
view operations on each Docking Station from a network computer, making it easy
to track instruments, print reports, set events and change parameters for any
location. The DS2 provides all the benefits of consistent automated calibration,
record keeping, battery recharging, and instrument diagnostics.
Troubleshooting
Diagnosing Common Problems
Problem Likely
Cause(s)
Display is blank…
The instrument has not been activated
No power
Unit resets (off/on)…
Internal error. Unit needs to be serviced.
Unit does not respond to
gas…
Check sensor opening for dirt or debris.
Replace sensor patch.
Calibrate instrument.