background image

Doc. SIE20167   

 

 

 

 

Rev. 2   

 

 

Page 

10 of  11 

PERFORMANCE 

CHARACTERISTICS 

B) RESIDENT FIRMWARE 

 

Test settings 

Recorded in a NVM 

Number of memories 

Maximum test duration that can be recorded 

15 h, with 15 s resolution 

Maximum test duration, not recorded in memory 

infinite 

Memory profile mode: maximum number of test steps 

20 

Memory profile mode: time and current resolution 

1 minute – 1 A 

Memory profile mode: maximum time and current steps 

600 minutes – 1300 A 

Test set control mode 

Via e push-button and 
menu on the display 

Measurements on the display 

. Date; 
. Time; 
. Internal discharge current; 
. External discharge current; 
. Battery voltage; 
. Ah discharged; 
. Elapsed test time. 

Test stop settings 

. Minimum voltage; 
. Maximum Ah; 
. Maximum test time; 
. System alarms; 
. Test stop from remote contact. 

Continue after an alarm 

YES 

Firmware upgrade 

YES 

System control 

Digital, by two microprocessors 

Test set protections 

. Heat sink over-temperature; 
. Fuse failure; 
. Fans failure; 
. Minimum battery voltage; 
. Maximum battery voltage; 
. Wrong battery voltage; 
. Overload; 
. Control circuit error; 
. Power circuits failure; 
. CAN-bus error; 
. External current metering error; 
. Manual emergency pressed; 
. USB interface error; 
. EEPROM memory error; 
. Firmware error. 

Reversed battery insertion protection 

YES 

Automatic cool down procedure at end of test 

YES 

 
 

 

Shop for Power Metering products online at:

1.877.766.5412

www.

PowerMeterStore

.ca

Содержание BTS200 MKII

Страница 1: ...Doc SIE20167 Rev 2 Date 27 03 2013 BTS200 MKII BATTERY TEST SET Shop for Power Metering products online at 1 877 766 5412 www PowerMeterStore ca...

Страница 2: ..._____________________ 6 2 2 Low voltage directive _______________________________________________________________________ 6 3 PERFORMANCE SUMMARY_______________________________________________________...

Страница 3: ...he external shunt it is also possible to use the real burden as the additional burden and to control the total discharging current in the selected mode The device is microprocessor based This allows t...

Страница 4: ...a shunt If a test is interrupted for instance because of a faulty contact or cell after the repair it is possible to continue the test this was not possible with the former device The test set firmwar...

Страница 5: ...ues f 900 5 MHz field 10 V m modulated AM 80 1 kHz EN 61000 4 4 Immunity tests for high speed transients burst Test values 2 kV peak 5 50 ns EN 61000 4 5 Immunity tests for surge Test values 1 kV peak...

Страница 6: ...le encountered during the day If during the discharge any of the programmed limits is trespassed the test is immediately stopped and the alarm contact closed Once the test is finished it is possible t...

Страница 7: ...limits 84 to 140 V DC 240 V range limits 140 to 270 V DC Maximum starting voltages on the 24 V range 20 to 35 V DC Maximum starting voltages on the 48 V range 34 to 65 V DC Maximum starting voltages o...

Страница 8: ...sors Thermal protection Independent from the microprocessors Dimensions 283 x 700 x 420 mm WDH Weight 39 kg without transport case Transport wheels YES Transport case dimension 330 x 900 x 600 mm WDH...

Страница 9: ...External discharge current Battery voltage Ah discharged Elapsed test time Test stop settings Minimum voltage Maximum Ah Maximum test time System alarms Test stop from remote contact Continue after a...

Страница 10: ...nges 40 A DC 10 mV A and 400 A DC 1 mV A Accuracy 1 5 up to 40 A 2 up to 400 A Maximum conductor diameter 30 mm PII12167 ELU200 MKII Same as BTS200 MKII without the local control PII21167 The followin...

Отзывы: