29
|
TECHNICAL SPECIFICATION
IM-Raptor-1.3.6-EN
8. TECHNICAL SPECIFICATION
DESCRIPTION
NUMBER OF SLOTS
Up to 4 slots
PORTS
ETHERNET NETWORK PORTS
Slot #1- 3—supports up to 8 x 10/100/1000 RJ45s or 8 x 100/1000 SFPs per slot
Slot #4—supports up to 4 x 10GB Base-X or 4x1GB Base-X Uplinks
SERIAL CONSOLE PORT
RS-232 in RJ-45 connector with console cable. 115200bps, 8, N, 1
USB PORT / SD CARDS
USB 3.0 for software and configuration update
OTHER HARDWARE FEATURES
Modular chassis with hot-swappable modules
Redundant hot-swappable power supplies
ALARM
Fault Contact: relay output to carry capacity of 1A at 24VDC
WARNING / MONITORING SYSTEM
Relay output for fault event alarming
Syslog Client for recording and Syslog Relay for forwarding Syslog messages
SMTP for event warning notification via email
Event level selection support
PHYSICAL CHARACTERISTICS
ENCLOSURE
IP 40 Galvanized steel
DIMENSIONS
486.15 (W) x 446.65 (D) x 44.36(H) mm (19.14 x 17.58 x 1.75 inch)
WEIGHT
9.8 kg (21.6 lbs.)
POWER
REDUNDANT INPUT POWER
Dual Power Supplies available in any combination of 24 VDC (Nom.), 48 VDC (Nom.), and
100-240VAC, 50/60 Hz, 100-240VDC (Nom.)
POWER CONSUMPTION
60 W
OVERLOAD CURRENT PROTECTION
Fast Acting Fuse 3.15 A (can only be replaced in the factory)
INSTALLATION CATEGORY
Overvoltage Category II, Pollution degree II
9. COMPLIANCE SPECIFICATION
DESCRIPTION
SPECIFICATION
ELECTROMAGNETIC EMISSIONS
FCC Part 15, CISPR 32 Common mode (Asymmetric mode), EN 55032 class A,
ELECTROMAGNETIC IMMUNITY
EN 61000-4-2 (ESD), EN 61000-4-3 (RS), EN 61000-4-4 (EFT),
EN 61000-4-5 (Surge), EN 61000-4-6 (CS), EN 61000-4-8
INDUSTRY STANDARDS
IEC 61850-3, IEEE 1613
OPERATING ENVIRONMENT
-40
o
C to +85
o
C (-40
o
to 185
o
F) EN 60068-2-21
STORAGE ENVIRONMENT
-40
o
C to +85
o
C (-40
o
to 185
o
F) EN 60068-2-14
OPERATING HUMIDITY
5% to 95% Non-condensing EN 60068-2-30
SHOCK
IEC 60255-21-2
VIBRATION
IEC 60255-21-1