iES28TG/iES28GF User Manual
178
iS5 Communications Inc.
Press
Start
to run the diagnostics. This will take approximately 5 seconds. If all ports are selected,
this can take approximately 15 seconds. When completed, the page refreshes automatically. Results
can be viewed in the cable status table. Note that VeriPHY diagnostics is only accurate for cables 7 - 140
meters long.
10 and 100 Mbps ports will be disconnected while running VeriPHY diagnostics. Therefore, running
VeriPHY on a 10 or 100 Mbps management port will cause the switch to stop responding until VeriPHY
is complete
.
Label
Description
Port
The port for which VeriPHY Cable Diagnostics is requested
Cable Status
Port: port number
Pair: the status of the cable pair
Length: the length (in meters) of the cable pair
5.11.6
SFP Monitor
SFP modules with DDM (Digital Diagnostic Monitoring) function can measure the temperature of the
apparatus, helping you monitor the status of connection and detect errors immediately. You can
manage and set up event alarms through DDM Web interface.