page 9
Z-397 WEB
www.ironlogic.me
6.1. Automatic mode detection.
6.2. Web Client Mode.
[COMMON]
MODE = WEB
[WEB]
SERVER = hw.guardsaas.com
PATH = /data.php
CONNECT_PERIOD = 20
RESCAN_PERIOD = 60
MAX_EVENT = 10
[RS485]
LINE1_BAUD = 19200
LINE2_BAUD = 57600
The converter settings allow operating the converter in WEB Client or TCP Server mode. In
these mode, the converter tries to connect to the webserver and listens for TCP connections
from remote software.
If an incoming TCP connection is detected, the converter stops trying to connect to webservers,
and vice versa, when successfully connected to a webserver, the converter stops accepting
incoming TCP connections.
The software and the webserver can fix the converter in a certain operation mode. Also, the
unneeded operation modes can be disabled in the configuration file.
In the Web Client mode, the converter manages and reads events from the controllers
connected via RS-485 channels. The converter connects to the webserver via HTTP, sending
controller status and event data to the server, and receiving back from it the control commands
to configure the controller parameters.
The data are sent via HTTP protocol, thus guaranteeing their delivery to the webserver from
virtually any LAN connected to the internet.
To set the converter into the Web Client mode:
-
Select the operation mode:
-
Set up the webserver parameters:
-
Set up the RS-485 baud rate:
RS-485
RS-485
RS-485
RS-485
WEB-server
DB
Internet
Internet
Internet