page 8
5.3. Configuration using the software.
5.4. Device firmware updates.
5.5. Reset to factory defaults.
6. OPERATION MODES
[NETWORK]
USE_DHCP=1
[NETWORK]
USE_DHCP = 0
LOCAL_IP = 192.168.1.100
NETMASK = 255.255.255.0
GATEWAY = 192.168.1.1
DNS = 192.168.1.1
All converter settings can be configured using the configuration software included on the
supplied CD.
The software allows searching for and configuring both the of the devices connected via LAN
and a local USB port. Its interface is designed as a wizard which easily allows to configure all
converter settings.
To update the device firmware, please connect the Z-397 WEB to a PC with a USB cable. The
device will be powered from USB port, so no external power is necessary. Do not connect more
than one Z-397 WEB converter to the same PC via USB at the same time!
After the converter is connected, the PC will detect it as a new removable drive labelled
“
Z-
397WEB
”
.
Write the new firmware file with name
“
xxx.ROM
”
(xxx varies between versions) into the
removable drive's root folder. After write operation completes, properly disconnect the device
from USB and power it up as usual. The firmware update process now begins; during the
update, the indicators will display
“
running lights
”
. After the update is finished, the device restarts
itself and thereafter is ready to work.
To reset the device to factory defaults, use LOCK switch. When the device is powered via
adapter or USB port, the CONVERTER STATUS LED will turn amber for about 1 s. During this
time, flip the LOCK switch three times. Each flip will turn one more indicator to amber. When all
indicators are on, all the user defined settings in the configuration file will be replaced with their
factory defaults.
Another way to reset the device to factory defaults is by writing a file with name CLEAR.TXT into
the USB removable drive's root folder.
Note: All parameter values in this chapter are for illustration only. In real operation, your
parameter values will depend on actual system configuration.
In all operation modes, you need to correctly configure the network settings in the configuration
file.
-
If using a local DHCP server on the LAN:
-
If using a static IP, additional parameters are required for the LAN configuration. Example:
Z-397 WEB