Страница 2: ...This file was converted to PDF format If you are interested in a Microsoft PowerPoint formatted file send a request to pm_eps nmci usmc mil...

Страница 3: ...ING AFTER OPERATION CHECKS 20 WATTAGE GUIDE 6 OPERATING INSTRUCTIONS 21 VEHICLE CONSIDERATIONS 7 TESTING THE QP 1800 22 MILITARY VEHICLE BATTERIES 8 POWERSAVE MODE 23 GENERAL SAFETY PRECAUTIONS 9 ENAB...

Страница 4: ...to Marine Corps units for installation on the following USMC HMMWV models HMMWVA2 M1123 Troop Cargo Variant Heavy HMMWV M1097A2 HMMWV ECV M1152 Expanded Capability Vehicle HMMWV ECV M1165 Expanded Ca...

Страница 5: ...age operating range High and low battery shutdown will engage if DC voltage falls below 20 VDC or exceeds 32 VDC Continuous Power 1800W Surge Power 2900W Output Frequency 60Hz Output Waveform True Sin...

Страница 6: ...er 1 per system NATO Cable 1 per system Case 1 per system Battery Terminal Covers 2 per system Vibration Isolators 4 per system Operator s Manual 1 per system MEG125 Replacement 1 Spare per system 32V...

Страница 7: ...500 114600 00 NATO Cable 6150 01 497 2515 SL 3 11460A 123 114600 00 Transportation Case 7050 01 551 0600 MI 11460 OI 1 160 114600 00 Mounting Bracket Part 287A125 CAGE 78535 Job Aid Over Packed with Q...

Страница 8: ...153 IISR radio set This charger consists of four six station charging assemblies As pictured the QP 1800 is capable of supporting all four charging assemblies DO NOT ADD ANY ADDITIONAL LOADS WHEN OPER...

Страница 9: ...WATTS WATTS Microwave Oven 625 Watts 800 625 Commercial Radio 0 50 200 Hand Drill 1 4 inch 500 350 Color Television 300 300 Laptop Computer 50 200 50 200 VCR 50 50 Printer 100 100 Coffee Maker 1750 1...

Страница 10: ...When the vehicle is running the battery is recharged and in most conditions the QP 1800 will supply power as long as there is fuel to run the vehicle In vehicle engine off situations the QP 1800 draws...

Страница 11: ...corrosion tight connections and no frayed cables HAWKER 6T SERIES OPTIMA The OPTIMA battery is not authorized for installation in vehicles The OPTIMA is authorized for generator use only The preferre...

Страница 12: ...ult Make sure existing vehicle electrical wiring is in good condition Do not operate the QP 1800 if it has been damaged in anyway Disconnect DC power from the inverter before attempting any preventive...

Страница 13: ...Fault Circuit Interrupter GFCI built into the duplex outlet The use of power strips IS NOT recommended If required closely monitor the power and battery voltage as the load increases The system has a...

Страница 14: ...l panel can be removed and re attached in different orientations to match the various mounting options Vibration Isolators must be installed to prevent damage to the inverter The QP 1800 requires a mi...

Страница 15: ...ATION OF THE QP 1800 The QP 1800 must be mounted in one of the three approved orientations shown Mounting in one of the two prohibited configurations could allow foreign objects to drop into the AC re...

Страница 16: ...1800 using the vehicle mounting bracket top right or directly to the top of the wheel well bottom right When the wheel well contains air conditioning components use of the vehicle mounting bracket is...

Страница 17: ...securing ancillary devices Devices should be whenever practical secured with straps Avoid the use of AC extension cord s wherever possible If extension cords must be used they must be three 3 conduct...

Страница 18: ...tighten until snug Verify polarity or the MEG 125 internal fuse will be blown see page 26 Slide battery terminal covers over POS NEG cables Connect SLAVE Cable to vehicle To disconnect first unplug c...

Страница 19: ...wering off vehicle accessories it is necessary to make an additional grounding connection between the grounding point on the vehicle and the grounding rod to make connection with the earth The off veh...

Страница 20: ...Page 17 QP 1800 FRONT PANEL On Off O I Rocker Switch Control Panel LCD Display Circuit Breaker Duplex AC Outlet GFCI Ground Fault Circuit Interrupter...

Страница 21: ...Page 18 QP 1800 REAR PANEL Input Terminals 2 Ground Lug Serial Number Mounting holes used to install Isolators 2 on each side not shown...

Страница 22: ...STAL DISPLAY LCD Displays battery input current and voltage numerically A multi segment bar graph displays actual output power in watts when a load is operated Initially it displays the model number f...

Страница 23: ...inverter for loose or missing mounting screws Check vibration isolators for obvious damage or excessive wear Check NATO cable for obvious damage Check NATO cable for tight connections to inverter and...

Страница 24: ...ormation showing input voltage input current and output power When a load is connected the output power watts is displayed in bar graph form 3 Once the standard display screen is shown the QP 1800 is...

Страница 25: ...the power up sequence on the display Input current and input voltage should be displayed STEP 3 Plug a test load into the QP 1800 outlet The load should function and the output power bar graph should...

Страница 26: ...watts with no load In the POWERSAVE mode the QP 1800 transmits a pulse every 2 5 seconds to detect if a load has been applied Full output power is available with the detection of a load The unit will...

Страница 27: ...the control panel displays POWERSAVE OFF turn the switch back to the O position wait for approximately three seconds and then turn the switch back to the I position again The initial power up informa...

Страница 28: ...icate high and low voltage conditions as shown below DC Input Over Voltage Alarm DC Input Over Voltage Shut down DC Input Under Voltage Alarm DC Input Under Voltage Shut down 31 6 VDC 32 0 VDC 21 0 VD...

Страница 29: ...es for capacitors to discharge Remove screws from top cover 2 Phillips and lift off Use 20 PSI compressed air to blow out dust Measure resistance of MEG125 fuse verify a blown fuse remove and replace...

Страница 30: ...ry voltage too low Charge battery Manually reset inverter by turning switch to O then to I again OVERLOAD SHUTDOWN Battery current too high probable AC overload Reduce load on the inverter Disconnect...

Страница 31: ...CAL INDICATOR Circuit overload condition existed in excess of 15A Turn system off remove load reset circuit breaker and restart system Then reapply load GFCI TRIP MECHANICAL INDICATOR Ground fault con...

Страница 32: ...oltage shutdown Recharge vehicle batteries check connections and cable Turn vehicle on to run alternator No output voltage no voltage indication Inverter switched to O No battery power to inverter Rev...

Страница 33: ...t overload condition existed in excess of 15 amps Turn system off remove load reset circuit breaker and restart system Reapply load GFCI trip Mechanical Indicator Ground fault condition occurred Turn...