This document is the property of IRFTS. It shall not be reproduced or shared with third party without agreement IRFTS
dimension
Y
dimension
A
1
2
3
4
5
6
7
7178
Number of
modules in height
System vertical step
Warning : Please check
the PV module
compatibilty list on :
www.irfts.com
Dimension Y
1020
1058
2078
3098
4118
5138
6158
E.g.: (1020 x (3-1)) 956 102 = 3098
Dimensions of the PV field
(Visible part of installation)
7)
2) Calculate the height of the visible field
b) Determination the dimension Y
12
Dimension of the visible field
= dimension Y + dimension A
a) a) Determination of dimension A (Bottom flashing batten)
The « C » dimension is the Minimum batten width necessary to avoid
reverse slope on the bottom flashing. It’s possible to use a wider
batten, this will simply raise up the PV field
Example:
Dimension of the photovoltaïc field
PV fi el d centered on rake di recti on
Gutter / eave installation
Step
: Step of the system in rake direction, see table below
Nby
: Number of line of PV module
Field height (mm)
Y
= Step x (
Nby
-1) + 956 + 102
Roof inclination (°)
Minimum batten width C dimension
(mm)
Mini A dimension
(mm)
10 to 12
250
260
13 to 16
220
230
17 to 19
180
190
20 to 24
150
160
25 to 50
120
130
Model "M-1" 60 6 Cells "Landscape
NOTE: For adjusting the tiles above the PV field, it may be necessary to increase
dimension A to raise the field (see Annexe 3 on p. 57-58).
Adjustment of tiles
above the PV field