This document is the property of IRFTS. It shall not be reproduced or shared with third party without agreement IRFTS
0°
0°
Specific position of the reference support batten
for PV field at the gutter/eave
« M” to be measured on the roof by observing the
conditions described here
X (mm)= 260(mm) + M
Reference support batten(d)*
* Reference nomenclature
9.2.3)
24
Reverse slope FORBIDDEN
PV field positioned at the gutter/eave
The low part of PV field (with the gutter) must imperatively be on the same plan as the flooring of the
system.
In the contrary case the dimension of 260 mm is not applicable any more.
It is necessary to
move up the PV field in the slope direction.
The dimension of positioning must be redefined.
Modèle “M-1” 60 Cellules 6" Paysage
X (mm)= 260(mm) + M