background image

 

 

Author:  RRi 

Page  -  48  - 

Version  1.0 

Date:  10-2019 

BLANKOM-IPQAM-801_User_Manual_ENv1.0.docx 

 

IPQAM-801 DVB-C A/C Modulator IP to QAM User Manual 

 

Safety instructions 

Read the safety instructions carefully before assembling or commissioning the device and ensure that you 
comply with them
 
1.    Installation 

 

Danger: The device may only be installed and started up by competent people (see EN 60065)

 

Danger: The device and the peripheral distribution devices must be earthed properly (potential 
equalization) in accordance with EN 60728-11 before 
Commissioning and remain earthed even when the device is dismantled. 

 

Danger: The device may not be installed on a flammable base (risk of fire)

 

Danger: Only connect the device to a socket that is installed correctly and connected to devices that has 
an earth conductor   
(Depending on Model andUsage). 

 

Danger: Plan the assembly or installation location to ensure that children cannot play with the device 
and its connections.   
There is a risk of electric shock (Danger of death)

 

Danger: Select an assembly or installation location in which fluids or objects cannot get into the device 
under any circumstances (e.g. condensation, water for watering plants, etc.). 

 

Danger: Ventilation slots and refrigeration units are important function elements on the devices. If 
devices have refrigeration units or ventilation slots, you must ensure that they are never covered or built 
over. Also ensure that there is sufficient air circulation around the device.    This prevents possible 
damage to the device and the risk of fire due to overheating. Ensure a minimum of clearance of 20cm 
between the device and other objects. 

 

Danger: The assembly or installation location must allow all connected cables to be laid safely. Cables 
and power supply cables must not be damaged or crushed by any objects. Furthermore, ensure that 
cables are not laid in the immediate vicinity of sources of heat (e.g. radiators, other electrical devices, 
fireplaces, etc.) (Risk of fire)(risk of electric shock danger of death) 

 

Danger: In order to prevent damage to the device, as well as possible subsequent damage (risk of fire)
devices intended for installation on the wall are only permitted to be installed on a level surface and not 
above head height

 

Warning: (Only for optical transmitters and their peripheral distribution devices) Never look directly or 
indirectly into the laser beam. Only connect the device to the power supply once all optical lines are 
connected securely. 

 

Warning: The safety regulations in the relevant current standards EN 60728-11 and EN 60065 must be 
complied with. 

 

Warning: Comply with all applicable national safety regulations and standards. 

 

Warning: The device's mains plug must be easily accessible at all times. 

 

Warning: Follow all instructions in the device-specific operating manual 

2.    Operation 

 

Danger: The device is only permitted to be operated in dry rooms in a non-tropical climate. In damp 
rooms or outdoors, there is the risk of short circuits (risk of fire) or electric shock (danger of death)

 

Danger: Do not insert any objects through the ventilation slot. Risk of electric shock (danger of death)

 

Danger: Do not put any containers filled with liquid (e.g. vases) on the device. There is a risk of electric 
shock (danger of death) or (risk of fire)

 

Danger: No open sources of fire such as burning candles are permitted to be placed on the device (risk 
of fire)

Содержание BLANKOM IPQAM-801

Страница 1: ...Installation and Operation Instructions IPQAM 801 8x UHD HD SD IP2QAM Multiplexer Modulator in DVB C Annex A C QAM...

Страница 2: ...as IPTV Streaming technologies and standards Disclaimer No part of this document may be reproduced in any form without the written permission of the copyright owner The contents of this document are s...

Страница 3: ...PTER 3 NETWORK INTERFACE SETUP 10 3 IPQAM LOGIN 10 3 1 MANAGEMENT PROGRAM 10 BEFORE USING 10 OBTAIN THE PROGRAM 10 3 1 INSTALLATION OF NET FRAMEWORK 10 3 1 4 NETWORK CONFIGURATION BASICS 13 3 2 GENERA...

Страница 4: ...KOM IPQAM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual 7 ENTSORGUNG 52 INSTALLATION GUIDE FOR F CONNECTORS 52 INSTALLATION AND SAFETY INSTRUCTIONS MONTAGE UND SICHER...

Страница 5: ...cascading or monitoring the Transportstream IGMP multicast Query support Video over IP applications like CCTV to DVB C Multiplex RTSP HLS UDP to MPEG TS Bandwidth 1 15MHz 8 05MHz Symbol Rate up to 70...

Страница 6: ...ible protocol IP V4 RTSP HLS UDP HLS HTTP Live Streaming RF Output Impedance 75 Connector BNC Test Port 20dB Frequency 48 863 MHz Output level 120 dB V Adjustable 0 20dB ASI Output Number of ASI outpu...

Страница 7: ...ludes the NMS Management status LED s and a FAN this needs to be kept open for air cooling purpose Rear RESET Button can be used to restore default settings RF Test Output 20dB attenuated RF Out pleas...

Страница 8: ...ree of dust or dirty The cover should be securely fastened do not open the top case of the products when the power is on After use securely stow away all loose cables external antenna and others 2 2 P...

Страница 9: ...es for window Wall It can be covered with wallpaper or brightness less paint Fire Protection Fire alarm system and extinguisher Power Requiring device power air conditioning power and lighting power a...

Страница 10: ...THE PROGRAM You can get the latest version of this management program from our service it is a freeware and green software that is you can run it directly without an installation process Note If you...

Страница 11: ...Author RRi Page 11 Version 1 0 Date 10 2019 BLANKOM IPQAM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual Figure 1 Start installation Figure2 Agreement acceptance...

Страница 12: ...Author RRi Page 12 Version 1 0 Date 10 2019 BLANKOM IPQAM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual Figure 3 Installing Figure 4 Installation finished...

Страница 13: ...sslink cable eventually or network interface should support MDI MDX better using a at least Gigabit Ethernet 1000BaseT switch and use a ping command to confirm they are on the same network segment I e...

Страница 14: ...eams by VLC VLC is somehow stupid and do not recognize via which Ethernet RJ45 or WIFI IP address Source it can grab the Stream The difference is to manually set the METRIC values The lower the Value...

Страница 15: ...Author RRi Page 15 Version 1 0 Date 10 2019 BLANKOM IPQAM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual Insert admin as the password than click OK...

Страница 16: ...Version 1 0 Date 10 2019 BLANKOM IPQAM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual So now you can search the unit in your network Windows should not act as an own...

Страница 17: ...Author RRi Page 17 Version 1 0 Date 10 2019 BLANKOM IPQAM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual usually it will find...

Страница 18: ...thor RRi Page 18 Version 1 0 Date 10 2019 BLANKOM IPQAM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual add it And it will appear in the list Simply connect to it Succe...

Страница 19: ...AM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual Notice the bottom window Shows the actual status of your IP streams coming in Now READ from the IPQAM And you will se...

Страница 20: ...019 BLANKOM IPQAM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual You can change the values according to your need But need to APPLY them to let them take effect You al...

Страница 21: ...801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual DVB RF settings We should go to QAM Parameters first to adjust maximum capacity of our Multiplexed Datastream FIRST READ...

Страница 22: ...ead of 10 So 5 Mbit should be left in the calculations of your stream reception to avoid the distortion of all channels transmitted when heavy bitrate peaks are overloading the channel Please adjust t...

Страница 23: ...of the CATV receivers lieke STB or TV sets Also the TV sets sometimes need to be set to a different country to enable its DVB C Channelplan at all Note We recommend to control and check the configured...

Страница 24: ...C Modulator IP to QAM User Manual See the null pakets of the DVB TS is constant according to the max datarate of the QAM DVB C settings whilke the content is fluktuating which depends on the Video str...

Страница 25: ...mode of setting the Time Date tables accordingly Apply will update the TS TDT TOT table Actually the software is not capable of reading that from the Input Streams and update that to the multiplexed T...

Страница 26: ...ease uncheck to insert the Character Table because that is not recommended and will not work actually Please don t tick the Insert Char table type while Chinese need this others not Also the HEX Gener...

Страница 27: ...range as lowest as possible by i e using a Band Filter to exclude these bandwidth and later add this 4x RF channels and combine both networks after or in it The TV sets or DVB C STB s would read the N...

Страница 28: ...ator IP to QAM User Manual But now something completely different Setting up the IP Input streams We are using as example some HDMI to IP encoders and some DVB SAT Streamers Please note that these han...

Страница 29: ...he So it s almost a good idea to monitor your input streams when configuring the multiplexer Note There are sooo many different sources which are acting slightly different from the standards for RTSP...

Страница 30: ...l_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual IP Input Parameter setting Addresses Ports and mode can be adjusted here Enabling and disabling as well as changing the Service provid...

Страница 31: ...out max Datarate is 51 Mb s incl Zero pakets on PID8191dec Please set the RF Center frequencies of the QAM channels according to the values shown in the Annex of this document and adjust the QAM outpu...

Страница 32: ...ecessary if essential parameters has been changed Firmware updates can be installed in case there are new versions available from the engineering fixing issues or adding improvements Please ask us if...

Страница 33: ...switching on device Checking the RF output level varies within tolerant range if it is necessary For RF devices Checking whether all signal cables have been properly connected Frequently switching on...

Страница 34: ...Author RRi Page 34 Version 1 0 Date 10 2019 BLANKOM IPQAM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual...

Страница 35: ...ht be very necessary TV sets are feeling well if the QAM RF level input would be not more than 75 80 dB v The Unit is transmitting at the output more than 110dB V so you should attenuate if you have n...

Страница 36: ...Author RRi Page 36 Version 1 0 Date 10 2019 BLANKOM IPQAM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual Found them...

Страница 37: ...rate self contained packets to remove the header duplication as in MPEG 4 s Header Extension Code HEC 36 This was achieved by decoupling information relevant to more than one slice from the media stre...

Страница 38: ...listed below The range of addresses between 224 0 0 0 and 224 0 0 255 inclusive is reserved for the use of routing protocols and other low level topology discovery or maintenance protocols such as ga...

Страница 39: ...eam arrives on a different port the server can safely ignore any traffic on ports that are not open Port numbers MUST be chosen so that don t clash with any existing services or ephemeral ranges The e...

Страница 40: ...P header consists of 4 fields each of which is 2 bytes 16 bits 1 The use of the fields Checksum and Source port is optional in IPv4 pink background in table In IPv6 only the source port is optional se...

Страница 41: ...CP destination port numbers are specified via explicit separate parameters using a signaling protocol or other means the application MAY disregard the restrictions that the port numbers be even odd an...

Страница 42: ...Author RRi Page 42 Version 1 0 Date 10 2019 BLANKOM IPQAM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual...

Страница 43: ...0 Date 10 2019 BLANKOM IPQAM 801_User_Manual_ENv1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual ANNEX MPEG MPEG PSI SI Information s We assume that the user is familiar with all abbreviat...

Страница 44: ...anal bereich Superband channels S 11 230 237 233 50 231 25 236 75 41 630 638 634 00 631 25 636 75 S 12 237 244 240 50 238 25 243 75 42 638 646 642 00 639 25 644 75 S 13 244 251 247 50 245 25 250 75 43...

Страница 45: ...5 5 01 3 3E 04 15 75 33 75 5 62 4 2E 04 16 76 32 75 6 31 5 3E 04 17 77 31 75 7 08 6 7E 04 18 78 30 75 7 94 8 4E 04 19 79 29 75 8 91 1 1E 03 20 80 28 75 10 00 1 3E 03 21 81 27 75 11 22 1 7E 03 22 82 26...

Страница 46: ...531 47 107 1 75 223 87 0 668 48 108 0 75 251 19 0 841 49 109 0 25 281 84 1 059 50 110 1 25 316 23 1 333 51 111 2 25 354 81 1 679 52 112 3 25 398 11 2 113 53 113 4 25 446 68 2 660 54 114 5 25 501 19 3...

Страница 47: ...rodukts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Attention La mise au...

Страница 48: ...nce of 20cm between the device and other objects Danger The assembly or installation location must allow all connected cables to be laid safely Cables and power supply cables must not be damaged or cr...

Страница 49: ...EN 60065 Before opening the device unplug the mains plug or disconnect the power supply otherwise there is a danger of death The device is only permitted to be connected to the power and operated when...

Страница 50: ...rhindern Sie m gliche Sch den am Ger t sowie Brandgefahr durch berhitzung Gew hrleisten Sie einen Mindestabstand von 20cm um das Ger t zu anderen Gegenst nden Gefahr Der Montage bzw Aufstellort mu ein...

Страница 51: ...W rme wie Sonnenschein Feuer oder dergleichen ausgesetzt werden Explosionsgefahr Warnung Verwenden Sie nur das Zubeh r des Herstellers oder Zubeh r mit identischen technischen Eigenschaften Warnung Be...

Страница 52: ...in den Hausm ll sondern m ssen gem Richtlinie 2002 96 EG DES EUROP ISCHEN PARLAMENTS UND DES RATES vom 27 Januar 2003 ber Elektro und Elektronik Altger te fachgerecht entsorgt werden Bitte geben Sie...

Страница 53: ...icht benutzte Teilnehmerausg nge sollten mit 75 Ohm Widerst nden z B EMK 03 abgeschlossen werden Verringerung der terrestrischen Signalwelligkeit Unused subscriber ports should be closed off by 75 Ohm...

Страница 54: ...chwierigkeiten zug nglich und benutzbar sein The mains plug must be easily accessible and operable Das Ger t kann nur durch Ziehen des Netzsteckers vom Netz getrennt werden The only reliable method of...

Страница 55: ...1 0 docx IPQAM 801 DVB C A C Modulator IP to QAM User Manual Contact IRENIS GmbH Hauptstr 29 31171 Nordstemmen Germany Phone 49 5069 4809781 Managing Director Dipl Ing Murad nol Commercial Register HR...

Отзывы: