Model 2100,2080,2000 Ver.14.0
13
―Jets‖ again, the pump1 will work at high speed. The low speed will turn off automatically after 4 hours,
(and if in its filter cycle duration time the pump1 will work in low speed) and the high speed will turn off
automatically after 15minutes. Press the third time ―Jets‖ the pump1 will stop.
Light
.
White light
Press the ―Light‖ button to turn on the lights, again to turn off it
。
Preset Filter Cycles
The first preset filter cycle begins 6 minutes after the spa is energized. The second preset filter cycle begins
12 hours later.
Filter duration is programmable for 2, 4, 6, or 8 hours or for continuous(24hours) To program,
press ―cool‖ or ―warm‖, then ―Jets.‖ Press ―cool‖ or ―warm‖ to adjust. Press ―Jets‖ to exit programming
6.2 Additional fuse and jump wire
There are one set additional fuses for the control box in the package, adhered on one white
board fixed on the frame, in pump area, in case any fuse in box is burnt can be replaced in
time.
When the spa delivered setting power services configuration is 2phase or 3phase, the jump
wire which removed from the control box are also put in this fuse package.
OR
OR
Additional fuses position