11
Chapter 5 – Adjusting Settings in the Menu
The ParticleScan Pro/CR has 14 menus which allow the user to set a range of parameters. To access these menus, press the
MENU key one to 14 times. To fast exit a menu at any time and get back to the measurement screen, you may press the
SAMPLE key at any time.
Chapter 5 – Adjusting Settings in the Menu
5.1
Location Menu [Loc]
The Location Menu allows the user to assign a location number from 1–256 to any data that is logged.
To change the location number, press the MENU key once until the display shows [Loc]. Press and hold the ENTER key for
two seconds until the location number starts to flash. Then use the UP or DOWN key, to select the desired location
number. To confirm the selection, press and hold the ENTER key for two seconds, until the location number stops flashing.
5.2
Data Logging Menu [Log]
The Data Logging Menu allows the user to log data to the ParticleScan’s internal memory. A user can set this function to
be on or off. Whether data logging is currently on or off is indicated by the status of the Data Log indicator. To turn the
data logging on or off, press the MENU key until the display shows [Log].
Press and hold the ENTER key for two seconds until [on] or [off ] selection starts to flash. Use the UP or DOWN key to select
the desired setting. Confirm the selection by pressing and holding the ENTER key for two seconds, until the selection
stops flashing.
5.3
Delete Data Menu [dAtA]
The Delete Data Menu shows how many data points have been logged to the ParticleScan memory and allows to erase
the logged data. The ParticleScan can log a maximum of 14,336 data points.
To view the number of data points logged to the ParticleScan internal memory, press the MENU key until the display
shows [dAtA]. To delete the logged data, press and hold the ENTER key for two seconds until [dEL_dAtA] flashes on the
display. Press and hold the ENTER key for two seconds to confirm the deletion of all logged data. After the deletion of
logged data the display will show [dAtA___0].
5.4
Full Memory Menu [FULL]
The Full Memory Menu allows the user to select what should happen when the ParticleScan’s data log memory is full.
[FULLstop] means that once the maximum number of data points have been logged, data logging will stop. [FULLcycl]
means that once the maximum number of data points has been logged, newly logged data will overwrite the oldest
ParticleScan data logged.
To change the Full Memory Setting, press and hold the ENTER key for two seconds until the [stop] or [cycl] selection starts
to flash. Use the UP or DOWN key to select the desired setting. Confirm your selection by pressing and holding the ENTER
key for two seconds until the selection stops flashing.
5.5
Concentration Units Menu [Con]
The Concentration Units Menu allows the user to select whether the particle concentration is displayed in particles per
cubic foot [Con__CF], particles per liter [Con__Lit] or particles per cubic meter (1000 liter) [Con1000L].
To change the concentration units, press and hold the ENTER key for two seconds until the [CF], [1000L] or [L] selection
starts to flash. Use the UP or DOWN key to select the desired setting. Confirm your selection by pressing and holding the
ENTER key for two seconds until the selection stops flashing.
Содержание ParticleScan CR
Страница 30: ...30 Notes...
Страница 31: ...080312_IQ_MA_PSPPSCR_US...