![IQ Gate Systems IQ-500 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/iq-gate-systems/iq-500/iq-500_installation-and-instruction-manual_2089481021.webp)
(
The De-Icing mode is a revolutionary new feature that automatically
increases the initial speed as well as the total amperage that is provided to
the gate operator when certain conditions, including temperature, are met.
)
(
The Motor Diagnostics option is an extraordinary feature that can allow
precise adjustment of the motor maximum output force. When M1 or M2
diagnostics are turned on, upon exiting the menus, the display will reflect the
motor amperage high and voltage low in real time when the motor is running.
At the end of the cycle, the highest amperage and lowest voltage that was
last detected will be displayed. By using this feature, proper adjustment to
the open and close force settings can be obtained. Be sure to turn the
diagnostic features off when not required
)
Motor Drive Menu
•
Number
of
Operators
in System = 1 or 2
•
Operator 1 ‘IQ’ = IQ Gate(default) or Standard (the Standard option does
not require the feedback from an encoder from the motor)
•
M-1 Open Force = user selectable amperage level from 00.1 to 16.0
Default=10.0
amps
•
M-1 Close Force = user selectable amperage level from 00.1 to 16.0
Default=10.0
amps
•
Force
Delay=
0.5
(
recommended
) this is the selectable time from .5
seconds up to 2 seconds in which the amperage may be reached or
exceeded before the gate reverses due to a motor open or close force
alarm
•
M-1 Max Speed = user selectable maximum motor speed from 10% to
100%
•
M-1 Min Speed = user selectable minimum motor speed from 10% to 90%
•
M-1 Open Delay = sets the desired open delay from 0.0 seconds to 5.0
seconds
•
M-1 Close Delay = sets the desired close delay from 0.0 seconds to 5.0
seconds
•
M-1 Acceleration Step Size = sets the rate of motor acceleration- the
higher the rate, the faster the ramp up to the maximum set speed
•
M-1 Deceleration Step Size = sets the rate of motor deceleration- the
higher the rate, the faster the ramp down to the minimum set speed
•
Operator 2 ‘IQ’ = IQ Gate or Standard
All M-2 options are the same as M-1
Exit the sub-menu