Auxiliary Settings / Enter to View/Adjust
•
Aux Input Terminal
(These are available programmable inputs that can be programmed to take
on the function that is selected when the AUX terminal is activated)
o
Open
o
Safe
o
Shadow
o
Fire
o
Close
o
Photo Eye Close (stops the gate from closing but doesn’t reverse
the gate)
o
Aux Out 1 (momentary activation of Aux 1 output relay)
o
Aux Out 2 (momentary activation of Aux 2 output relay)
o
Toggle Aux 1 (toggles Aux 1 output relay on/off)
o
Toggle Aux 2 (toggles Aux 2 output relay on/off)
o
7-day Open Timer Off (turns off the 7-day open timer until the next
open schedule)
•
Aux 1 Output Relay
•
Aux 2 Output Relay
(These are available options for the Aux 1/2 output relays to perform if
selected)
o
Pulse on Open Limit (a 2 second relay activation on the open limit)
o
Pulse on Close Limit (a 2 second relay activation on the close limit)
o
Hold on Open Limit (latches the relay on the open limit)
o
Hold on Close Limit (latches the relay on the close limit)
o
Pulse on Motor Open (a 2 second relay activation when gate is
opening)
o
Pulse on Motor Close (a 2 second relay activation when gate is
closing)
o
Hold on Motor Open (latches the relay when gate is opening)
o
Hold on Motor Close (latches the relay when gate is closing)
o
Hold on UL-325 Alarm (latches the relay upon a UL-325 alarm)
o
Aux Input Received (activates the relay when the Aux input is in
use)
o
AC Power Loss (activates the relay upon AC power loss detection
which is measured when the gate receives less then 23.5 VDC)
o
Low DC Power (activate the relay upon low DC power detection, a
value of equal to or less then 75% of full power supplied)
o
Thermostat Engaged (activates the relay when the thermostat is
engaged)
o
Maintenance Request (activates the relay upon a maintenance
request)
19