B. Error Status Codes
The following error codes may be displayed in the
FAULTS
menu when the meter is
placed in Diagnostic Mode:
Battery Low
– appears when the meter’s battery drops below 4000 mV
Card Stuck
– indicates an object inserted into the card reader
Coin Path Blocked
– indicates an object obstructing the path of the coin or the validator
not being present
OSC Fault
– appears when a coin is detected but is not validated
Time or Config error
– the time on the meter is off by a more than 24 hours or the
configuration on the meter is incorrect
The following error codes may be displayed during a communication session in the
COMMS TEST
menu when the meter is placed in Diagnostic Mode:
GSM Not Found
– meter cannot communicate with the GSM radio
CME ERROR 10
– SIM not inserted
CME ERROR 107
– GPRS service not allowed
CME ERROR 553
– context already activated
CME ERROR
555
– activation failed
CME ERROR 557
– cannot setup socket
CME ERROR 559
– time out in opening socket