Replace the battery
Battery replacement is likely required approximately every 2 years, depending on
operating conditions. There is an additional cable required to connect the battery, which
is a three socket to a six pin battery adapter cable.
Method 1 (No tools required)
If your meter is equipped with a battery compartment cover, follow the steps below:
1. Remove the battery compartment cover
2. Disconnect and remove the old battery from the battery extension cable or the
main board connector terminal if extension cable is not present
3. Install and plug in the replacement battery
Method 2 (requires a Phillips-head screw driver):
1. Unscrew and remove the coin validator
2. Remove the screws at the rear of the meter
3. Disconnect and remove the faulty battery from the main board connector terminal
4. Install and plug in the replacement battery
5. Insert and tighten all screws and re-insert the coin validator