Replace the coin slot
The coin entry slot can easily be changed in order to accept coins of different sizes. To
replace the coin slot, remove the Card Entry Slot (as shown below) and the Coin
Validator. The coin slot should easily slide out. Insert the new coin slot with the notch-
side up, replace the coin validator, and the card entry slot to complete the installation.
Force a meter update
In order to force a meter to call in to the management system to get a firmware update,
configuration update, or simply to test communications:
1. Enter Diagnostic mode by pressing the diagnostic switch located below the
OK
button of the keypad or using the Diagnostic Card
2. Scroll through the menus to
Comms Test
and press
OK
3. The meter will attempt to communicate with the server. Do not press any buttons
on the keypad during this process as this may interrupt the communication
session. See
Comms Test
for an example of a typical session.
4. Once the meter communication session completes, press
CANCEL
until the
meter returns to operating mode