background image

1

1.

1.

1.

1. Brief

Brief

Brief

Brief introduction:

introduction:

introduction:

introduction:

.......................................................................................... 2

1.1

1.1

1.1

1.1

System

System

System

System and

and

and

and model

model

model

model description

description

description

description

.................................................... 2

1.2

1.2

1.2

1.2

Description

Description

Description

Description of

of

of

of commonly

commonly

commonly

commonly used

used

used

used symbols

symbols

symbols

symbols

...................................3

1.3

1.3

1.3

1.3

LCD

LCD

LCD

LCD display

display

display

display and

and

and

and function

function

function

function of

of

of

of buttons:

buttons:

buttons:

buttons:

........................................ 5

1.4

1.4

1.4

1.4

Product

Product

Product

Product specification

specification

specification

specification and

and

and

and performance

performance

performance

performance

.................................... 6

2.

2.

2.

2. Installation

Installation

Installation

Installation

........................................................................................................ 8

2.1

2.1

2.1

2.1

Unpacking

Unpacking

Unpacking

Unpacking and

and

and

and inspection

inspection

inspection

inspection

.............................................................8

2.2

2.2

2.2

2.2

Input

Input

Input

Input and

and

and

and output

output

output

output power

power

power

power cords

cords

cords

cords and

and

and

and protective

protective

protective

protective earth

earth

earth

earth ground

ground

ground

ground

installation

installation

installation

installation

.....................................................................................................8

2.3

2.3

2.3

2.3

Installation

Installation

Installation

Installation

.........................................................................................8

2.4

2.4

2.4

2.4

Operating

Operating

Operating

Operating procedure

procedure

procedure

procedure for

for

for

for connecting

connecting

connecting

connecting the

the

the

the long

long

long

long backup

backup

backup

backup time

time

time

time

model

model

model

model UPS

UPS

UPS

UPS with

with

with

with the

the

the

the external

external

external

external battery

battery

battery

battery

.................................................... 11

3.

3.

3.

3. Operation

Operation

Operation

Operation and

and

and

and operating

operating

operating

operating mode

mode

mode

mode

................................................................. 11

3.1

3.1

3.1

3.1

Operation

Operation

Operation

Operation

......................................................................................... 11

3.1.1.

3.1.1.

3.1.1.

3.1.1. Turn

Turn

Turn

Turn on

on

on

on the

the

the

the UPS

UPS

UPS

UPS with

with

with

with utility

utility

utility

utility power

power

power

power supplied

supplied

supplied

supplied (in

(in

(in

(in Line

Line

Line

Line

mode/AC

mode/AC

mode/AC

mode/AC mode)

mode)

mode)

mode)

................................................................................. 11

3.1.2.

3.1.2.

3.1.2.

3.1.2. Turn

Turn

Turn

Turn on

on

on

on the

the

the

the UPS

UPS

UPS

UPS with

with

with

with no

no

no

no utility

utility

utility

utility power

power

power

power supplied

supplied

supplied

supplied (in

(in

(in

(in Battery

Battery

Battery

Battery

mode)

mode)

mode)

mode)

....................................................................................................12

3.1.3.

3.1.3.

3.1.3.

3.1.3. Turn

Turn

Turn

Turn off

off

off

off the

the

the

the UPS

UPS

UPS

UPS with

with

with

with no

no

no

no utility

utility

utility

utility power

power

power

power supplied

supplied

supplied

supplied (in

(in

(in

(in Battery

Battery

Battery

Battery

mode)

mode)

mode)

mode)

....................................................................................................12

3.2

3.2

3.2

3.2

Operating

Operating

Operating

Operating mode

mode

mode

mode

..............................................................................13

3.2.1.

3.2.1.

3.2.1.

3.2.1. Utility

Utility

Utility

Utility power

power

power

power mode

mode

mode

mode

................................................................. 13

3.2.

3.2.

3.2.

3.2.2.

2.

2.

2. Battery

Battery

Battery

Battery mode

mode

mode

mode

........................................................................... 14

3.2.

3.2.

3.2.

3.2.3.

3.

3.

3. Bypass

Bypass

Bypass

Bypass mode

mode

mode

mode

...........................................................................14

3.2.

3.2.

3.2.

3.2.4.

4.

4.

4. Abnormality

Abnormality

Abnormality

Abnormality mode

mode

mode

mode

..................................................................15

3.2.

3.2.

3.2.

3.2.5.

5.

5.

5. Backup

Backup

Backup

Backup time

time

time

time for

for

for

for the

the

the

the standard

standard

standard

standard model

model

model

model

.................................15

3.2.6.

3.2.6.

3.2.6.

3.2.6. Communication

Communication

Communication

Communication Port

Port

Port

Port

............................................................. 16

4.

4.

4.

4. Battery

Battery

Battery

Battery Maintenance

Maintenance

Maintenance

Maintenance

.................................................................................... 18

5.

5.

5.

5. Notes

Notes

Notes

Notes for

for

for

for battery

battery

battery

battery disposal

disposal

disposal

disposal and

and

and

and battery

battery

battery

battery replacement

replacement

replacement

replacement

........................... 18

6.

6.

6.

6. Trouble

Trouble

Trouble

Trouble shooting

shooting

shooting

shooting instructions

instructions

instructions

instructions

................................................................... 19

6.1

6.1

6.1

6.1

Warning

Warning

Warning

Warning code

code

code

code and

and

and

and Fault

Fault

Fault

Fault code

code

code

code

.....................................................19

6.2

6.2

6.2

6.2

Simple

Simple

Simple

Simple problem

problem

problem

problem phenomena

phenomena

phenomena

phenomena and

and

and

and solutions

solutions

solutions

solutions

............................ 21

Содержание IP Compact Series

Страница 1: ... Best of online in a compact product www ipower re Applications UPS Online IP COMPACT Available in 1 6 KVA ...

Страница 2: ...tility utility power power power power supplied supplied supplied supplied in in in in Line Line Line Line mode AC mode AC mode AC mode AC mode mode mode mode 11 3 1 2 3 1 2 3 1 2 3 1 2 Turn Turn Turn Turn on on on on the the the the UPS UPS UPS UPS with with with with no no no no utility utility utility utility power power power power supplied supplied supplied supplied in in in in Battery Batter...

Страница 3: ...ers and Peripherals are thus powered entirely by the UPS In the event of power failure the maintenance free batteries power the inverter This manual is applicable to the following models 1 The 6KS is a standard model with inbuilt battery hereinafter called 6KS 2 The 6KL is a long backup time model which is able to connect with the external battery bank hereinafter called 6KS 3 The 10KS is a standa...

Страница 4: ...e Front and Back View of 6KVA single phase Front and Back View of 10KVA single phase L OUTPUT N L INPUT N L BYP BATTERY G PE LINE BYP RS232 EPO SNMP MAINTENANCE SWITCH PARALLEL PORT MUTE Front Panel Fan Manual Bypass Breaker Terminal AC Breaker Bypass Breaker Intelligent Slot Parallel Port RS232 EPO Emergency Power Off N INPUT OUTPUT BATTERY L L N L BYP MAINTENANCE SWITCH SNMP G PE LINE BYP MADE I...

Страница 5: ... Bypass Breaker Terminal MUTE RS232 EPO PARALLEL PORT RS232 EPO Emergency Power Off Parallel Port C INPUT OUTPUT BATTERY N L N L BYP B A G PE LINE BYP C INPUT OUTPUT BATTERY N L N L BYP B A LINE BYP MAINTENANCE SWITCH PARALLEL PORT EPO RS232 SNMP M UTE Front Panel Terminal Manual Bypass Breaker Intelligent Slot RS232 EPO Emergency Power Off Parallel Port AC Breaker Bypass Breaker Fan ...

Страница 6: ...d It will light with alarm when UPS has fault 6 Output indicator green It will light when the output is available 7 Inverter output indicator green It will light when the Inverter is working 8 Battery is working yellow It will light when battery supply power to UPS Screen is to view and choose the functions or items 9 ON OFF Press it longer than 1 second the UPS will start or turn off 10 Enter Thi...

Страница 7: ...0kVA 8kW 10KS 50 60 176 276 Or 80 150 Vac 50A max 192 240VDC 10kVA 8kW 10KL 50 60 176 276 Or 80 150 Vac 50A max 192 240VDC 10kVA 8kW 3 phase10KS 50 60 304 478 Or 138 260Vac 50A max 192 240VDC 10kVA 8kW 3 phase10KL 50 60 304 478 Or 138 260Vac 50A max 192 240VDC 15kVA 12kW 3 phase15KL 50 60 304 478 Vac 75A max 192 240VDC 20kVA 16kW 3 phase20KL 50 60 304 478 Vac 100A max 192 240VDC Power rating Batte...

Страница 8: ...olerance Distortion Overload capacity Current crest ratio 1 0 8lag Synchronized 46 54Hz in Line mode AC mode 0 1 of normal frequency in Battery mode THD 3 Full load linear load 105 125 load transfers to bypass mode after 60s 125 150 load transfers to bypass after 30s 3 1 maximum Operating Operating Operating Operating environment environment environment environment Temperature Humidity Altitude St...

Страница 9: ...allation installation 1 1 1 1 Notes Notes Notes Notes for for for for installation installation installation installation 1 The UPS must be installed in a location with good ventilation far away from water inflammable gas and corrosive agents 2 Ensure the air vents on the front and rear of the UPS are not blocked Allow at least 0 5m of space on each side 3 Condensation to water drops may occur if ...

Страница 10: ...cle may be burned and destroyed 5 Connect the input and output wires to the corresponding input and output terminals according to the following diagram 6 Note you must make sure that the input and output wires and the input and output terminals are connected tightly the protective earth ground wire refers to the wire connection between the equipment which consumes electric equipment and the ground...

Страница 11: ...ON OFF position the UPS will charge the batteries automatically You can also use the UPS immediately without charging the batteries first but the backup time may be less than the standard value 11 If it is necessary to connect the inductance load such as a monitor or a laser printer to the UPS the start up power should be used for calculating the capacity of the UPS as its start up power consumpti...

Страница 12: ...ttery first if you connect the cable to the UPS first you may encounter the hazardous of electric shock 2 To complete the connection by plugging the connector of the external battery cable into the external battery socket of the UPS Do not attempt to connect any loads to the UPS now You should connect the input power wire to the right position first And then set the breaker of the battery pack in ...

Страница 13: ...e UPS will perform self diagnosis the Load Battery level LEDs will be turned on and then off one after another in ascending order then the INV LED will be turned off and Bypass LED will be turned on The UPS is working in Bypass mode 3 Upon completion of the above to turn it off output of electric current of the UPS is still present In order to cut off the output from the UPS simply cut off the uti...

Страница 14: ...LEDs will be turned on and alarm will keep twice every second You should get rid of some unnecessary loads one by one to decrease the loads connected to the UPS less than 90 of its nominal power capacity Note Please follow the following steps to connect the generator Activate the generator and wait until the operation is stable before supplying power of the generator to the UPS be sure that the UP...

Страница 15: ...creases and the battery voltage descends to the alarm level the buzzer will beep once every second to remind the users of in sufficient battery capacity and the UPS is soon going to shut down automatically Then the load operations should be carried out promptly and the loads should be eliminated one by one 3 2 3 2 3 2 3 2 3 3 3 3 Bypass Bypass Bypass Bypass mode mode mode mode The display panel in...

Страница 16: ...S is operating in abnormal mode Please refer to the troubleshooting in section 6 for detail 3 2 3 2 3 2 3 2 5 5 5 5 Backup Backup Backup Backup time time time time for for for for the the the the standard standard standard standard model model model model The backup time of the long backup time model is dependent on the external battery pack capacity and the load level as well as other factors The...

Страница 17: ...ve remote management of the UPS through internet intranet Please contact your local distributor for further information RS232 RS232 RS232 RS232 interface interface interface interface 1 The following are the descriptions and pin assignment of RS232 DB 9 port Baud rate 2400bps Data bit 8 bit Ending bit 1bit Parity bit None DB 9 pin assignment backup backup backup backup time time time time of of of...

Страница 18: ...es dry contact closure signal OPEN or CLOSE Following are the pin assignment and the descriptions of AS400 card PIN1 UPS failure normally open active close PIN2 summary alarmPIN3 ground PIN4 Remote shutdown PIN5 Common PIN6 Bypass active relay close PIN7 Battery low PIN8 UPS On relay close PIN9 Utility Power failure normally open active close RS232 RS232 RS232 RS232 Interface Interface Interface I...

Страница 19: ...rmal conditions the battery life lasts 3 to 5 years In case if the battery is found not in good condition earlier replacement should be made Battery replacement should be performed by qualified personnel Replace batteries with the same number and same type of batteries Do not replace the battery individually All the batteries should be replaced at the same time following the instructions of the ba...

Страница 20: ... voltages Therefore before any maintenance and repairs work is carried out switch off the breaker of the battery pack or disconnect the jumper wire of connecting between the batteries 8 Batteries contain hazardous voltage and current Battery maintenance such as the battery replacement must be carried out by qualified personnel 6 6 6 6 Trouble Trouble Trouble Trouble shooting shooting shooting shoo...

Страница 21: ...INVERTER short circuit Check the inverter part I N V V O L T L O W Inverter voltage low Check the inverter I N V V O L T H I G H Inverter voltage high Check the inverter I N V O V E R L O A D Inverter voltage overload Check the inverter B U S V O L T O V E R BUS over voltage Check the bus B U S V O L T U N D E R BUS under voltage Check the bus I N V O V E R T E M P Inverter over temperature Check ...

Страница 22: ...ttery Battery anode and cathode connection in reverse Checking and reconnect Fans stop running Fans failed or board of fan damaged Contact with technician for repair UPS not start when turn on UPS Switch failed Check switch Power supply board failed Contact with technician for repair UPS no output when there is no mains Battery switch didn t turn on or failed Check switch Battery capacity is not e...

Страница 23: ...ut fuse of charging board are failed Buzzer alarming for a long time FAULT light is bright Heat sink of inverter is over temperature Check if the heat dissipation is good or not UPS internal failed Contact with technician 键入文档的引述或关注点的摘要 您可将文本框放置在文档中的任何位置 可 使用 文本框工具 选项卡更改重要引述文本框的格式 ...

Отзывы: