background image

                                                                                                            Ytterbium Fiber Laser, Model YLR-200-AC

 

                                                                                                      

IPG Laser GmbH, 2009                                                                                           

 

Proprietary Information. All rights reserved 

Rev. Date 08-12-2009 

 

21 

echoed  back,  a  delimiter,  and  then  either  the 
power in watts, “Off” if the laser is off”, or “Low” 
if  the  power  is  below  the  reliable  measurement 
threshold of the laser. 

(Indicates that the output power is 96 
watts) 
 
Sent:             “ROP” 
Response:     “ROP: Off” 
(Indicates that emission is off) 
 
Sent:             “ROP” 
Response:     “ROP: Low” 
(Indicates that the output power is 
below the accurate measurement range 
of the laser) 

RFV 

Read current software revision.   

Sent:             “RFV” 
Response     “RFV: 1.0.147 “ 

RCT 

Read  Laser  Temperature  –  Reads  the  internal 
temperature of  the  laser.   The response  will  be 
an echo of the command, a delimiter of “: “, and 
the temperature in degrees centigrade. 

Sent:             “RCT” 
Response:    “RCT: 34.5” 

RET 

Read  Elapsed  Time  –  Reads  the  elapsed  time 
the  laser has been on.   The time  is returned in 
minutes. 

Sent:              “RET” 
Response:     “RET: 1105” 

RSN 

Read Serial Number – Reads the serial number 
of the device.  

Sent:             “RSN” 
Response     “RSN: 6103081 “ 

STA 

Read device status – The  status is reported as 
a bit-encoded 32-bit word. Undefined bits or bits 
defined  as  “Reserved”  can  be  in  any  state  and 
should  be  ignored.  Each  of  the  bits  has  the 
following meaning: 
Bit 0  -     Reserved 
Bit 1  -     0 = Normal operation 
               1 = Overheat 
Bit 2  -     0 = Emission Off 
               1 = Emission On 
Bit 3  -     0 = Back Reflection OK 
               1 = High Back Reflection  
Bit 4  -     0 =  External Mode Disabled 

1 = External Mode Enabled 

Bit 5  -     Reserved 
Bit 6  -     0 = Normal operation 
               1 = Module Disconnected 
Bit 7  -     0 = Module OK 
               1 = Module Failed 
Bit 8  -     0 = Aiming Beam OFF 
               1 = Aiming Beam ON 
Bit 9  -     Reserved 
Bit 10 -    Reserved  
Bit 11 -    0 = Power Supply is On 
               1 = Power Supply is Off 
Bit 12 -    0 = Modulation Disabled 
               1 = Modulation Enabled. 
Bit 13 -   Reserved 
Bit 14 -   Reserved 
Bit 15 -   0 = Emission is not starting 
              1 = Emission  Starting 
Bits 16-17 - Reserved 
Bit 18-     0 = Hardware Emission Control 
              Disabled 
              1 = Hardware Emission Control 
              Enabled 

Sent:              “STA” 
Response:     “STA: 4100” 
 
This translates to the following: 
4100 = 0x1004, so bits 2 and 12 are 
set. This means that emission is on and 
modulation is enabled. 
 
 

Содержание YLR-200-AC

Страница 1: ...YLR 200 AC Ytterbium Fiber Laser User s Guide...

Страница 2: ...sult from its use IPG shall not be liable for errors contained in this document or for incidental or consequential damages in connection with the furnishing performance or use of this material IPG gra...

Страница 3: ...acture of 90 This guarantees you as user a high grade of competence and reliability High output power excellent beam quality high stability and mobility are outstanding predicates of the fiber laser T...

Страница 4: ...reserved Rev Date 08 12 2009 4 Table of Contents 1 General Safety Information 5 2 Description 9 3 Accessories 10 4 Environmental Conditions and Precautions 11 5 Front and Rear Panel Description 16 6...

Страница 5: ...ily harm to you and or others Do not proceed beyond the WARNING sign until you completely understand and meet the required conditions CAUTION Refers to a potential product hazard It requires a procedu...

Страница 6: ...ING No operator serviceable parts inside Refer all servicing to qualified IPG personnel To prevent electrical shock do not remove covers Any tampering with the product will void the warranty WARNING F...

Страница 7: ...e the radiation being invisible the beam may cause irreversible damage to the cornea Laser safety eyewear is not provided with this instrument but must be worn at all times while the laser is operatio...

Страница 8: ...ety Labels and Labeling Locations The figures below show the labels and their placement on the product Aperture Label Location Output fiber exit port housing Explanatory Labels sample Location Top cov...

Страница 9: ...and efficient allowing them to be replacing bulky and less efficient lasers Main application are welding cutting and brazing Main Features High quality fiber output High power Reliable long lifetime C...

Страница 10: ...mation All rights reserved Rev Date 08 12 2009 10 3 Accessories Part Quantity Note YLR 200 AC 1 Ytterbium Fiber Laser Set of parts for external interface connector 1 For operating and controlling the...

Страница 11: ...ed of specified quality and clean Any dust on the output can burn and lead to a damage to the laser CAUTION Always switch the laser off if working with the optical output mounting it into a fixture vi...

Страница 12: ...ate 08 12 2009 12 DANGER STRONG ISOLATED LASER BEAMS For lasers equipped with optical isolator option WARNING During laser operation optical radiation may exit from the laser isolator ports Please sec...

Страница 13: ...cleaning the fiber connectors can become contaminated Clean the fiber connectors only according to the instructions in this manual For cleaning a fiber connector you need the following materials 1 Ko...

Страница 14: ...o the microscope 5 Check the surface carefully If some contamination is visible on the quartz block cleaning is necessary Try to blow away the dust with compressed air from the side Put a drop of Isop...

Страница 15: ...a cleaning with acetone was done CAUTION Risk of damage at the fiber connectors Misuse inaccurate cleaning use of not intended chemicals can lead to damage at the fiber connector These damages are no...

Страница 16: ...turns OFF the internal main power supply in the case of emergency 2 POWER key 3 position key switch Middle OFF Clockwise LOCAL Counter clockwise REMOTE 3 START button When pressed turns ON the interna...

Страница 17: ...24 VDC 2 Interlock Channel 2 Contact Closure 24 VDC 3 Interlock Channel 2 Contact Closure 24 VDC 4 Interlock Channel 1 Contact Closure 24 VDC 5 RS232 Tx 6 RS232 Rx 7 RS232 Com 8 Remote Laser Power Key...

Страница 18: ...e emission is enabled 13 17 19 21 22 Reserved Should be disconnected from each other and from other pins of the connector 9 IDENTIFICATION LABEL Contains information about the device 10 1FU 2FU Electr...

Страница 19: ...face 2 To set Hardware Emission Control Disabled send the command DLE via RS 232 interface OPERATION MODES In both control regimes LOCAL and REMOTE there are three operation modes of the laser 1 ACC M...

Страница 20: ...ommand is found a response of BCMD will be sent The commands are shown here as all uppercase for clarity the actual commands are not case sensitive A space character is also shown between the command...

Страница 21: ...N Read Serial Number Reads the serial number of the device Sent RSN Response RSN 6103081 STA Read device status The status is reported as a bit encoded 32 bit word Undefined bits or bits defined as Re...

Страница 22: ...OD Enable Modulation Enables the modulation control input Sent EMOD Response EMOD DMOD Disable Modulation Disables the modulation control input Sent DMOD Response DMOD EEC Enable External Control Enab...

Страница 23: ...by pressing Emission button on the front panel of the laser By pressing SET control button the operator will select current SETPOINT and then can set the required current value using and OK buttons Pr...

Страница 24: ...key is in ON position it is possible to switch the internal main power supply using START button on the front panel If the key is in REM position the START button on the front panel is deactivated In...

Страница 25: ...ternal main power supply is automatically switched off Send reset error command RERR and if the message does not disappear contact a representative from IPG Laser for assistance 3 High back reflection...

Страница 26: ...re of the laser module drops in the operating range 6 Module disconnected Bit 6 ERROR MODULE DISCONNECTED This means that digital data communication with the laser module inside the device is broken T...

Страница 27: ...ED CALL FOR SERVICE This means that the system has detected an error which is considered to be critical The power supply and laser emission will be switched off at that Neither reset command RERR nor...

Страница 28: ...y Limitations This warranty excludes products parts including fiber connectors or equipment which have been tampered with opened disassembled opened or modified by persons other than IPG personnel mis...

Страница 29: ...ration of the equipment or driver software will be uninterrupted or error free Not all driver software has gone through IPG Laser s normal quality control or product purposes but is provided to users...

Страница 30: ...rned in a suitable container Any damage noted upon receipt of the unit must be documented for appropriate claim against the carrier IMPORTANT Never send any product back to IPG without a Return Mercha...

Страница 31: ...or one way freight costs to IPG Laser IPG Laser will reimburse Buyers for applicable reasonable third party freight costs and IPG Laser will pay for freight return cost back to the Buyer 3 Non Warrant...

Страница 32: ...care to retain all packaging materials and inserts Particular care must be taken when removing the unit from the packing case to ensure that the fiber optic cable is not broken and damaged A comprehen...

Отзывы: