8
Certified Test Report No. LSC A511 Computed by LSC Program “Test-Lite”, Dec. 9, 2004
IPEX Non-metallic ceiling mount light fixture Cat. No. LVPF150C with clear glass jar lens and plastic protective guard.
One 100w 120v coated A19 soft white incandescent lamp.
Lumen Rating = 1470 LMS.
For photometric files, visit ipexna.com.
ANGLE
MEAN CP
LMS
ANGLE
MEAN CP
LMS
0
91
90
107
5
91
9
95
112
121
10
89
100
111
15
88
25
105
108
114
20
85
110
104
25
81
38
115
99
98
30
82
120
91
35
86
54
125
82
73
40
91
130
71
45
96
74
135
59
46
50
101
140
45
55
105
94
145
31
20
60
109
150
17
65
112
111
155
7
4
70
114
160
1
75
116
122
165
0
0
80
116
170
0
85
114
123
175
0
0
90
107
180
0
ZONE
LUMENS
% LAMP
% LUMINAIRE
0 – 30
71
4.84
6.32
0 – 40
125
8.52
11.12
0 – 60
293
19.96
26.07
0 – 90
649
44.18
57.71
40 – 90
524
35.67
46.58
60 – 90
356
24.22
31.63
90 – 180
475
32.38
42.29
0 – 180
1125
76.56
100.00
180
150
120
90
60
ACROSS
45
ALONG
30
200
0
100
ANGLE
LUMINANCE
0
14732
(4299)
30
7668
(2238)
40
7631
(2227)
45
7754
(2263)
50
7917
(2310)
55
8109
(2366)
60
8297
(2421)
65
8463
(2470)
70
8654
(2525)
75
8895
(2596)
80
9020
(2632)
85
9107
(2658)
CC
80
70
50
30
10
0
WALL
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
RCR
0
.83
.83
.83
.83
.78
.78
.78
.78
.67
.67
.67
.57
.57
.57
.48
.48
.48
.44
1
.72
.67
.63
.59
.67
.62
.59
.55
.53
.50
.47
.45
.42
.40
.37
.35
.33
.29
2
.64
.57
.50
.45
.59
.52
.47
.42
.44
.40
.36
.37
.33
.30
.30
.27
.25
.21
3
.58
.48
.41
.36
.53
.45
.38
.33
.38
.33
.28
.31
.27
.24
.25
.22
.20
.16
4
.52
.42
.35
.29
.48
.39
.33
.27
.33
.28
.24
.27
.23
.20
.22
.19
.16
.13
5
.48
.37
.30
.24
.44
.34
.28
.23
.29
.24
.19
.24
.20
.16
.19
.16
.13
.11
6
.44
.33
.26
.20
.40
.30
.24
.19
.26
.20
.16
.21
.17
.14
.17
.14
.11
.09
7
.40
.29
.22
.17
.37
.27
.21
.16
.23
.17
.14
.19
.15
.11
.15
.12
.09
.07
8
.37
.26
.20
.15
.34
.24
.18
.14
.21
.16
.12
.17
.13
.10
.14
.11
.08
.06
9
.34
.24
.17
.13
.31
.22
.16
.12
.19
.14
.10
.16
.12
.09
.13
.09
.07
.05
10
.32
.22
.15
.11
.29
.20
.14
.11
.17
.12
.09
.14
.10
.07
.12
.08
.06
.04
Tested according to IES procedures. Test distance exceeds five times the greatest luminous opening of luminaire.
Determined in accordance with current IES published procedures Luminaire input watts = 96.2
Laboratory result may not be representative of field performance. Ballast factors have not be applied.
CANDLEPOWER SUMMARY
AVERAGE LUMINANCE DATA
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
ZONAL, LUMENS AND PERCENTAGES
Efficiency = 76.6% S/MH = 1.5 SC = 1.5