Certified Test Report No. LSC A514 Computed by LSC Program “Test-Lite”, Dec. 13, 2004
IPEX Non-metallic ceiling mount light fixture Cat. No. LVPL26C with clear glass jar lens and plastic protective guard.
One 26w quad compact fluorescent lamp. One Hatch 120v 1-lamp electronic ballast no. FR-2600
Lumen Rating = 1825 LMS.
For photometric files, visit ipexna.com.
ANGLE
MEAN CP
LMS
ANGLE
MEAN CP
LMS
0
23
90
120
5
26
3
95
122
132
10
34
100
118
15
41
12
105
111
117
20
48
110
103
25
55
26
115
94
93
30
64
120
83
35
73
46
125
72
65
40
83
130
60
45
91
71
135
47
37
50
99
140
35
55
105
94
145
24
16
60
112
150
15
65
117
116
155
7
4
70
122
160
2
75
125
132
165
0
0
80
126
170
0
85
125
136
175
0
0
90
120
180
0
ZONE
LUMENS
% LAMP
% LUMINAIRE
0-30
40
2.22
3.70
0-40
86
4.77
7.92
0-60
251
13.80
22.94
0-90
635
34.80
57.83
40-90
548
30.04
49.91
60-90
383
21.00
34.89
90-180
463
25.38
42.17
0-180
1098
60.18
100.00
180
150
120
90
60
ACROSS
45
ALONG
30
120
0
60
ANGLE
LUMINANCE
0
3683
(1075)
30
5980
(1745)
40
6997
(2042)
45
7397
(2158)
50
7764
(2266)
55
8116
(2368)
60
8491
(2478)
65
8871
(2589)
70
9226
(2692)
75
9572
(2793)
80
9841
(2872)
85
10035
(2929)
CC
80
70
50
30
10
0
WALL
70
50
30
10
70
50
30
10
50
30
10
50
30
10
50
30
10
0
RCR
0
.66
.66
.66
.66
.61
.61
.61
.61
.53
.53
.53
.45
.45
.45
.38
.38
.38
.35
1
.56
.52
.49
.45
.52
.48
.45
.42
.41
.38
.36
.34
.32
.30
.28
.27
.25
.22
2
.50
.43
.38
.34
.46
.40
.35
.31
.34
.30
.27
.28
.25
.22
.23
.20
.18
.15
3
.44
.37
.31
.26
.41
.34
.29
.24
.28
.24
.21
.23
.20
.17
.19
.16
.14
.11
4
.40
.32
.26
.21
.37
.30
.24
.20
.25
.20
.17
.20
.17
.14
.16
.13
.11
.09
5
.37
.28
.22
.17
.33
.26
.20
.16
.21
.17
.14
.18
.14
.11
.14
.11
.09
.07
6
.33
.24
.19
.15
.30
.23
.17
.13
.19
.15
.11
.15
.12
.09
.12
.09
.07
.05
7
.30
.22
.16
.12
.28
.20
.15
.11
.17
.12
.09
.14
.10
.07
.11
.08
.06
.04
8
.28
.19
.14
.10
.26
.18
.13
.09
.15
.11
.08
.12
.09
.06
.10
.07
.05
.03
9
.26
.18
.12
.09
.24
.16
.11
.08
.13
.10
.07
.11
.08
.05
.09
.06
.04
.03
10
.24
.16
.11
.08
.22
.15
.10
.07
.12
.08
.06
.10
.07
.05
.08
.05
.03
.02
Tested according to IES procedures. Test distance exceeds five times the greatest luminous opening of luminaire.
Determined in accordance with current IES published procedures Luminaire input watts = 22.8
Laboratory result may not be representative of field performance. Ballast factors have not be applied.
CANDLEPOWER SUMMARY
AVERAGE LUMINANCE DATA
COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD
EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
ZONAL, LUMENS AND PERCENTAGES
Efficiency = 60.2% S/MH = 3.8 SC = 3.7