background image

6

ANGLE

MEAN CP

ANGLE

MEAN CP

0

230

90

46

5

230

95

39

10

228

100

33

15

224

105

27

20

220

110

21

25

212

115

16

30

204

120

12

35

196

125

8

40

296

130

6

45

173

135

4

50

161

140

3

55

147

145

1

60

132

150

1

65

113

155

0

70

94

160

0

75

72

165

0

80

59

170

0

85

52

175

0

90

46

180

0

180

150

120

80

160

240

90

60

ACROSS

45

ALONG

30

80

40

10

CANDLEPOWER SUMMARY

Tested according to IES procedures. Test distance exceeds five times the greatest luminous opening of luminaire. 
Determined in accordance with current IES published procedures Luminaire input watts = 15
Laboratory result may not be representative of field performance. 

CC

80

70

50

30

10

0

WALL

70

50

30

10

70

50

30

10

50

30

10

50

30

10

50

30

10

0

RCR

0

1.16

1.16

1.16

1.16

1.12

1.12

1.12

.89

1.05

1.05

1.05

.98

.98

.98

.92

.92

.92

.89

1

1.04

.98

.93

.88

1.00

.95

.90

.71

.88

.85

.81

.83

.80

.77

.77

.75

.73

.70

2

.94

.84

.77

.70

.90

.81

.75

.58

.76

.70

.65

.71

.66

.62

.66

.63

.59

.526

3

.85

.73

.64

.57

.81

.71

.63

.48

.66

.59

.54

.62

.56

.51

.58

.53

.49

.46

4

.77

.64

.55

.48

.74

.62

.54

.41

.58

.51

.45

.55

.48

.43

.51

.46

.42

.39

5

.71

.57

.48

.41

.68

.55

.47

.35

.52

.44

.39

.49

.42

.37

.46

.40

.36

.33

6

.65

.51

.42

.35

.63

.50

.41

.31

.47

.39

.33

.44

.37

.32

.41

.36

.31

.29

7

.60

.46

.37

.31

.58

.45

.36

.27

.42

.35

.29

.40

.33

.28

.38

.32

.27

.25

8

.56

.42

.33

.27

.54

.41

.33

.24

.39

.31

.26

.37

.30

.25

.35

.29

.24

.22

9

.52

.38

.30

.24

.50

.37

.29

.22

.35

.28

.23

.34

.27

.23

.32

.26

.22

.20

10

.49

.35

.27

.22

.47

.34

.27

.20

.33

.26

.21

.31

.25

.20

.30

.24

.20

.18

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

ZONE

LUMENS

% LUMINAIRE

0 – 30

183

19.9

0 – 40

306

33.2

0 – 60

572

62

60 – 90

250

27.1

70 – 100

179

19.5

90 – 120

88

9.6

0 – 90

821

89.1

90 – 180

101

10.9

0 – 180

922

100

ANGLE

LUMINANCE

0

17955

45

11624

55

10405

65

8802

75

6423

85

5585

AVERAGE LUMINANCE DATA

ZONAL, LUMENS AND PERCENTAGES

Certified IESNA LM-79 Test Report for LLED-15/LVPE-LED/LVPF-LED

Sceptalight LED products include the LLED-15 Retrofit Light Engine and LVPE-LED and LVPF-LED light fixture models.
One LLED-15 Light Engine 15W 120v frosted globe. 
For photometric files, visit ipexna.com.

Содержание SCEPTALIGHT Series

Страница 1: ...ipexna com NONMETALLIC LIGHT FIXTURES Technical Information LED Light Fixtures Incandescent Light Fixtures Compact Fluorescent Light Fixtures Fixtures E L E C T R I C A L S Y S T E M S...

Страница 2: ...Typical applications include The fixtures are ideal for illuminating walkways bridges tunnels refrigeration coolers and task areas where corrosion of metallic fixtures are a concern like the food pro...

Страница 3: ...ed for the specific group of gas vapor or dust for which it is approved Hazardous Location Use Sceptalight fixtures are listed and approved for Hazardous Location use in Class I Div 2 Groups A B C D C...

Страница 4: ...TING TEMPERATURE 40 C to 40 C DIMMABILITY RANGE down to 5 CRI 80 Temperature Codes The temperature marking specified by the T code on the fixture label indicates the maximum surface temperature of the...

Страница 5: ...manner that establishes an effective ground fault current path Several methods for effective bonding are provided within section 250 of the NEC for various types of applications such as Bonding at th...

Страница 6: ...63 59 526 3 85 73 64 57 81 71 63 48 66 59 54 62 56 51 58 53 49 46 4 77 64 55 48 74 62 54 41 58 51 45 55 48 43 51 46 42 39 5 71 57 48 41 68 55 47 35 52 44 39 49 42 37 46 40 36 33 6 65 51 42 35 63 50 4...

Страница 7: ...1 70 16143 4711 75 16541 4827 80 16860 4920 85 17187 5016 Tested according to IES procedures Test distance exceeds five times the greatest luminous opening of luminaire Determined in accordance with c...

Страница 8: ...5 75 8895 2596 80 9020 2632 85 9107 2658 CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 83 83 83 83 78 78 78 78 67 67 67 57 57 57 48 48 48 44 1 72 67 63 59 67 62 5...

Страница 9: ...0 5014 1463 75 5212 1521 80 5368 1566 85 5511 1608 CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 81 81 81 81 75 75 75 75 65 65 65 55 55 55 47 47 47 42 1 70 65 60...

Страница 10: ...7346 2144 75 7620 2224 80 7802 2277 85 7945 2319 CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 75 75 75 75 70 70 70 70 61 61 61 52 52 52 44 44 44 41 1 65 60 56 52...

Страница 11: ...589 70 9226 2692 75 9572 2793 80 9841 2872 85 10035 2929 CC 80 70 50 30 10 0 WALL 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 RCR 0 66 66 66 66 61 61 61 61 53 53 53 45 45 45 38 38 38 35 1 56...