6.     When you connect to the above IP Address it will launch the

   AP 

Configuration 

Tool.

  7. 

  Click on “Scan for Wireless Networks”.  The list will

 

   

populate with all available wireless networks in your area.  

 

8.  

Find the customers Wireless Network and select it.  If security 

 

   

credentials are required, you will be prompted to enter them.

  9.   You should now be connected to the customers Wi-Fi 
   Network.

Connecting to a Wireless Network (WPS)

Press the SW1 button (located on the top left side of the board) once, 
it should trigger the device to enter into WPS mode. LED 6 will blink 
as long as the device is in WPS mode.  Follow the router’s directions 
to turn WPS on. Typically, enabling WPS involves simply pressing a 
button labeled ‘WPS’ on the customer’s router or switch. Once the 
Wi-Fi device and the router recognize each other, LED 6 will go solid 
indicating it has connected. You can now press the SW1 button twice to 
indicate the signal strength of the device. 

Reset the Wireless Network (AP Configuration Tool)

Locate the button labeled SW1 on the top left of the board. When this 
button is pressed 3 times, it causes the device to perform a software 
reset and will allow you to perform the ‘AP Configuration Tool’ again. 

Dual-Path Alarm Communicator - Installation Guide ...............................................

Page 8

Содержание BAT-CDMA-WIFI

Страница 1: ...Rev 1 1...

Страница 2: ...services ipDatatel engineers and manufactures innovative security and automation devices for the alarm industry As a leader in the design and development of Cellular and IP connected products we offer...

Страница 3: ...details Programming for TELCO use on Vista Section Universal Wi Fi BAT as Sole Communicator 41 Enter Phone Number 43 Enter Account Number 193 Enter 1 0 Enable to turn on Address 20 GE NETWORX See pag...

Страница 4: ...isioning 9 Board Button Configuration 10 Pre Installation 10 Troubleshooting Diagnostic Information 13 Validating the Installation 13 Wiring Programming for Popular Panels 13 DSC Panel Wiring and Prog...

Страница 5: ...software enables remote manage ment of Honeywell and DSC alarm panels that are connected to the BAT CDMA WIFI Product Key Features Cellular Verizon CDMA and Wi Fi Communicator The BAT CDMA WIFI replac...

Страница 6: ...t runs from any Internet connected browser that supports flash Alarm Notifications via Text Push and Email The BAT CDMA WIFI provides notifications for alarm supervisory trouble open close and test si...

Страница 7: ...e A QuickStart Guide has been designed to make the BAT CDMA WIFI easily join the customer s Wi Fi Network This guide can be found at www ipdatatel com support php Connecting to a Wireless Network AP C...

Страница 8: ...r into WPS mode LED 6 will blink as long as the device is in WPS mode Follow the router s directions to turn WPS on Typically enabling WPS involves simply pressing a button labeled WPS on the customer...

Страница 9: ...es IP connectivity to the BAT CDMA WIFI Resolution The following steps will re provision the BAT CDMA WIFI with the Verizon network Service Provisioning Steps 1 To begin ensure that the device is powe...

Страница 10: ...sly attached to Should any pairing issues occur press the SW1 button 5 times to factory reset and start the pairing process over Pre Installation Hardware Registration Before installation of your BAT...

Страница 11: ...ion The BAT CDMA WIFI s signal collection requires the alarm control panel send Contact ID format signals from its digital dialer Wire the Telco side of the alarm control s Tip Ring to the BAT CDMA WI...

Страница 12: ...eractive Ready See Supported Panels section page 26 27 the following programming will provide full feature virtual keypad access allowing the customer to enter their code to arm disarm the system by w...

Страница 13: ...rching for a router in WPS mode Solid Indicates the device has found a router via WPS Mode LEDs 3 to 6 When connected to a Wi Fi Router Displays signal strength indicated on device startup and updated...

Страница 14: ...DSC Panel Wiring and Programming DSC Keybus Tip Ring Wiring Dual Path Alarm Communicator Installation Guide Page 14...

Страница 15: ...PC Link Connection This provides for remote downloader functionality with ipDatatel s Universal Downloader uDownloader software DSC PC Link Wiring Dual Path Alarm Communicator Installation Guide Page...

Страница 16: ...or BAT as Failover w Add l Com munication Device BAT as Dual Re porting w Add l Communi cation Device Code Summarization 015 Disable Option 7 If GSM Dis able Option 7 If Phone Line Enable Option 7 f G...

Страница 17: ...e Option 1 Enable Option 1 5 Enable Option 1 2 5 Options to turn on off maintenance for telephone 1 option 1 telephone 2 option 2 and alternate communications option 5 376 Enable Option 1 Enable Optio...

Страница 18: ...Vista Panel Wiring and Programming Vista Keybus Tip Ring Wiring Dual Path Alarm Communicator Installation Guide Page 18...

Страница 19: ...ng a Honeywell Vista for the BAT CDMA WIFI as Sole Communicator Sec For BAT as Sole Communicator Code Summarization 41 Enter Phone Number 43 Enter Account Number 49 Enter 5 For All Communications to B...

Страница 20: ...el manual for your particular application requirements Dual Reporting Setting to 5 sends all reporting to both primary and secondary 54 Enter 0 Enter 2 Enter 0 The time it takes for the communicator t...

Страница 21: ...GE Panel Wiring and Programming GE Keybus Tip Ring Wiring Dual Path Alarm Communicator Installation Guide Page 21...

Страница 22: ...oncept Programming on GE NetworX Section BAT as Sole Communicator Code Summarization Device 0 Location 0 Enter the Phone Number Device 0 Location 1 Enter Account Number Device 0 Location 2 Enter 13 Re...

Страница 23: ...ogram the panel Phone Number into the panel Program the Customers Account Number into the panel Program Reporting codes into the panel Program panel to transmit in Contact ID format For interactive ke...

Страница 24: ...m panel wiring is needed A programmable output on the alarm panel will be used to signal the BAT Y Tx terminal that the panel has entered Arm Disarmed state The Z1 output on the BAT CDMA WIFI will be...

Страница 25: ...r specific installation Honeywell Typical 56 program zone as type 77 80 Menu LED Outs Program 17 and 18 zone type 78 and 79 DSC PowerSeries Typical Section 001 Zone must be programmed as a 22 Section...

Страница 26: ...Vista 15CN 2 6 YES YES YES Vista 15P 2 6 YES YES YES Vista 15PCN 2 6 YES YES YES Vista 15PSIA 4 0 YES YES YES Vista 20P 2 6 YES YES YES Vista 20PCN 2 6 YES YES YES Vista 20PI 5 0 YES YES YES Vista 20P...

Страница 27: ...n should function properly as long as the control transmits Contact ID format through Tip Ring If the panel has the ability to use a Dedicated Open Zone that acts as a key switch you can Arm Disarm fr...

Страница 28: ...ll have no liability or obligation under this Limited Warranty or otherwise for merchantability or fitness for any particular use nor shall it extend its Limited Warranty if the product is altered or...

Страница 29: ...d including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules Th...

Страница 30: ...le Cet quipement g n re utilise et peut mettre des fr quences radio et s il n est pas install et utilise en conformit avec les instructions peut causer des interf rences nuisibles aux communications r...

Страница 31: ...ided 12v DC Typical Current 130 mA Max Current 185 mA Environmental Temperature Range 30 to 70 C 22 to 158 F Humidity 0 to 95 non condensing Physical Height 7 05 inches Width 4 45 inches Depth 1 5 inc...

Страница 32: ...IPD CDMA WIFI IM 3 15...

Отзывы: