Generic Key Switch Programming
Key switch state programming examples for DSC, Honeywell, and GE
NetworX for key switch and panel state program output operations are
provided below.
Most alarm panel manufacturers have the capability to configure a zone
as a key switch and generally have at least one on-board programmable
output that can be configured to activate on a number of different
control state conditions. Reference the alarm panel installation manual
for details for your specific installation.
Honeywell (Typical)
56 program zone as type 77
80 Menu LED Outs
Program 17 and 18 zone type 78 and 79
DSC PowerSeries (Typical)
Section 001 - Zone must be programmed as a 22
Section 009 - 05
DSC Alexor (Typical)
Wiring:
Terminal 5 -> I/01
Terminal 15 -> I/02
6.2k ohm resistor from Terminal 3 -> Terminal 5
Programming:
Section 009 - ‘05’/’22’
Section 013 - Enable 2 & Disable 1
Section 134 - Enable 14 (Press 9, then 6)
Section 206 - Enable Option 2.
Section 501 - Enable 3
GE NetworX (Typical)
Device ‘0’ Location 25, press * until you reach desired zone
Program zone as ‘11’
LED
Status
Device
‘0’
Location 47 Segment 1: 21
Location 47 Segment 2: 0