Vista Panel Programming
All alarm controls must be programmed to transmit Contact ID, and have
a Phone Number and Account Number in the Panel. See Supported
Panels section on page 26-27.
Programming when using TELCO (Recommended): Programming a
Honeywell Vista for the BAT-CDMA-WIFI as Sole Communicator:
Sec
For BAT as Sole
Communicator
Code Summarization
41
Enter Phone Number
43
Enter Account Number
49
Enter 5
For All Communications to BAT
54
Enter 0
No Delay Between Communicators
55
Enter 0
Phone Line Communicates First
65 & 66
Enter 1
If you want Opening/Closing Reports
193
Enter 1, 0
Enable to turn on Address 20