![ipDatatel BAT-CDMA-WIFI Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/ipdatatel/bat-cdma-wifi/bat-cdma-wifi_installation-manual_2088591011.webp)
that was emailed upon your initial company registration.
• Navigate to ‘Dealer Menu’->’User Accounts’, then click ‘Create
Account.’
• Fill in the customer information.
• Click ‘Add Hardware.’
• Find and select the BAT-CDMA-WIFI you previously registered. You
may search it by MAC address.
• Follow other registration steps and options as found on this page,
then click ‘save’ to complete the registration.
Locating and Installing the BAT-CDMA-WIFI
The BAT-CDMA-WIFI connects to the alarm panel’s power connections,
telco, and keypad bus (if available) or key switch connections
(optional).
The BAT-CDMA-WIFI automatically seeks an IP address. There is no
need to program the customer’s router or switch.
Telco - Digital Dialer Connection
The BAT-CDMA-WIFI’s signal collection requires the alarm control
panel send Contact ID format signals from its digital dialer. Wire the
Telco side of the alarm control’s Tip & Ring to the BAT-CDMA-WIFI’s
Tip & Ring.
Virtual Keypad Connection
The BAT-CDMA-WIFI connects to most DSC, Honeywell, and GE
Networx alarm controls as a Virtual Keypad, allowing the customer
virtual keypad access after they authenticate using the customer
username and password you have assigned them in the pre-installation
phase. You will need to refer to the wiring diagram for your specific
panel for Data-in Data-out, YEL-GRN, or just Data. This connects to
the G/RX, Y/TX connections on the BAT-CDMA-WIFI.
Power Connection
The final step is to wire the alarm panel’s 12VDC auxiliary power
and ground to BAT-CDMA-WIFI positive (pin 3) and negative (pin 4)
terminals.