Chapter 4: Routine Maintenance
Use the Control Center to Gather the Calibration Data
1.
Open the FlexJet
Control Center
program.
2.
Select
Tools>Size Calibration
from the
Menu Bar
. The win-
dow in
Figure 27
will appear:
3.
Press the
Send Size Plot
button to print the factory stored
calibration box. The printer will print a box that is 40” (102-cm)
long on the X-axis and 30-in (76-cm) wide on the Y-axis.
4.
Precisely measure both sides (X) and the top and bottom (Y) of
the box and record the results. Better accuracy in measurement
equals better calibration.
5.
Take the average of the horizontal (Y) values by adding them
together and dividing by 2. Repeat this procedure for the verti-
cal (X) values.
Example
:
If X1 = 39.750-in and X2 = 39.700-in
The sum is 79.450-in (39.750-in + 39.700-in = 79.450-in)
The average is 39.725-in (79.450-in / 2 = 39.725-in)
The X calibration value is the average, 39.725-in
Enter the Calibration Data:
1.
Enter the measured values in the boxes in the
Calibration
win-
dow. Make sure the printer is in
START
(green light) mode.
Select the
Set Calibration
button.
2.
The Control Center will send the calibration values to the
printer and the new
Calibration Setting
will be displayed in
the boxes in the window pictured in
Figure 27
.
3.
Click on
Done
when finished.
Figure 28.
The Calibration box and measurements.
Y1
Y2
X1 X2
~40 in.
Only use
Reset Calibration
to
restore original factory calibration
settings.
Note
i
The factory-set calibration values
are written on a small sticker
inside the
Service Station
(
See
Figure 34
). To view them, turn
off the power, manually pull the
carriage out over the platen and
peer through the opening in the
right end cover. You’ll see a white
sticker in the back.
Hint
The
Get Plotter Data
button
will read the stored calibration
settings from the printer and dis-
play them in the
Factor
windows.
Hint
Содержание FlexJet
Страница 1: ...User Guide Ioline FlexJet ...
Страница 3: ...User Guide Ioline FlexJet ...
Страница 8: ......
Страница 20: ...20 Ioline FlexJet User Guide This page intentionally left blank ...
Страница 50: ...50 Ioline FlexJet User Guide Figure 34 Factory calibration values on the sticker inside the Service Station ...
Страница 64: ...64 Ioline FlexJet User Guide This page intentionally left blank ...