background image

 

 

31 

The HDDs are hot-swappable. No need to shut down the system for HDD installation 
and/or replacement when needed. 
 

Smart Fan Control

 

The fan modules possess a smart control feature set by the firmware to provide seven 
levels of speed RPM according to the detected system temperature. 
 

Zoning

 

This system support feature divides disk drives into two or more different groups 
depending on the system preference. Each group can own users-configurable number 
of HDDs independently. This feature enables single JBOD to serve multiple hosts. 
 

Cascading

 

There are cascading ports on the Expander for cascading another JBOD system to 
expand disk space when more space is required. 

 

 

4.3

 

Software Management 

4.3.1

 

System Management Structure 

InWin

’s JBOD Systems supports an out

-of-band Network Management feature, 

which enables a rich set of protocols and a flexible way for SAS Expander 
management anytime from anywhere. 
 

4.3.1.1

 

  Ethernet Management     

The Bridge Expander is equipped with a network management port 
allowing users to manage JBOD systems from a remote location. 
 
With a proper IP address setting, users can manage the system through 
Telnet, SSH, Web-GUI and SNMP remotely. 

 

 

Содержание IW-RJ472-05

Страница 1: ...IW RJ472 05 User s Manual...

Страница 2: ...Hard Drive 10 2 2 2 Removing a Hard Drive 11 2 3 Removing and Installing the Fan Module 12 2 3 1 Removing the Fan Module 12 2 3 2 Installing the Fan Module 13 2 4 Removing and Installing the PSU FAN...

Страница 3: ...binet External Cable Management Arm Installation 27 3 Expander Board Introduction Host Disk 28 3 1 Expander Board Host 28 3 2 Expander Board Disk 29 4 User Interface Introduction 30 4 1 Overview 30 4...

Страница 4: ...lated room and away from sources of heat including direct sunlight and radiators It should be kept away from sources of vibration or physical shock The space should be accommodated with a properly gro...

Страница 5: ...umper carefully and plug the jumper to cover the jumper pins on the backplane Once you need to remove the jumper grip the jumper and carefully pull without squeezing CAUTION To avoid damage and mainta...

Страница 6: ...ansion Port 6 x Mini SAS HD SFF 8644 for each 12G expander module Management Smart fan thermal monitor HDD monitor voltage monitor alarm warning SES Supports SES 2 SCSI Enclosure Service Maintenance S...

Страница 7: ...4 1 Product Introduction 1 1 Box Contents...

Страница 8: ...the IW RJ472 05 JBOD enclosure is a high density 4U rackmount storage chassis with 72 tool less bays dual hot swap SAS 12G expander modules six Mini SAS HD SFF 8644 for each 12G expander module six P...

Страница 9: ...LED Blue Solid on Press the button to activate chassis identification 3 Status LED Red Solid on System maintenance PSU fan malfunction 4 Drives Status LEDs for Bays 1 72 Follow the table below Drive...

Страница 10: ...Module 3 Fan Module 1 PSU FAN Module 10 Secondary expander Module 4 Fan Module 2 PSU FAN Module 11 Power Module Handle 5 Fan Module 3 PSU FAN Module 12 Power Switch 6 Fan Module 4 PSU FAN Module 13 PS...

Страница 11: ...al Downlink Connect to cascading JBOD 4 Expander Module Status LED Heartbeat 5 ID LED Button Press the button to activate chassis identification 6 Expander Serial Port RS 232 RS 232 Support 7 Network...

Страница 12: ...em from HDD overheating Step 1 Loosen the thumbscrews of the top cover Step 2 Pull the thumbscrews to release the top cover Slide and tilt the cover upward from the front and lift to remove Step 1 Ste...

Страница 13: ...over and pull it outward as a handle Step 2 Pull up the tray until it clicks Step 3 Fully insert the HDD into the tray from the correct disk port orientation Step 4 Align the HDD screw holes and plug...

Страница 14: ...the arrow on the tray Open the disk tray cover and pull it outward as a handle Step2 Pull up the tray until it clicks Step3 Pull the hard drive out carefully Step4 Lower the disk tray back Release th...

Страница 15: ...in fan modules that support hot swappable and redundant features which is easy to maintain with the tool less design 2 3 1 Removing the Fan Module Step 1 Loosen the thumbscrew of the fan module Step 2...

Страница 16: ...and three fan modules With this function the system is capable of still functioning if one of the modules fail To replace it the user only needs to release the failed module then insert a functional m...

Страница 17: ...Step 1 Step 2 2 4 2 Installing the PSU FAN Module Step 1 Push the PSU FAN module cage back until it clicks Step 2 Tighten the thumbscrew to secure the cage Step 1 Step 2 Push Pull Push PSU Fan PSU Fa...

Страница 18: ...to monitor and maintain the system Also the redundant module can minimize downtime should any on the expanders fail 2 5 1 Removing the Host Expander Module Step 1 Loosen the thumbscrew of the host ex...

Страница 19: ...o prevent the system from HDD overheating Step 1 Open the top cover of the chassis Please refer to 2 1 1 Step 2 Remove the cable from the disk expander module Step 3 Loosen the thumbscrew of the modul...

Страница 20: ...tep 1 Place the disk expander module into the cage until it clicks Step 2 Put the thumbscrew into position and tighten the thumbscrew Step 3 Connect the cable to the disk expander module Step 4 Close...

Страница 21: ...18 Step 2 Step 3 Connects the Cables Connects the Cables...

Страница 22: ...the stop Release the blue slide tab to unlock Step 2 Continue pulling the inner rail until the second stops Release the white slide tab to remove the inner rail Step 3 Pull the latch on the middle ra...

Страница 23: ...l the rail bracket pins that go into the front post holes on the rack until they click Step 5 The other side of the rail is symmetrical repeat the installation steps 1 4 Step 6 Once you would like to...

Страница 24: ...position release the blue slide tab again to continue Step 6 Push the chassis into position on the rack completely Make sure that the front end of the chassis is aligned with the edge of the rack to...

Страница 25: ...nal cable management arms 2 7 2 Mounting Bracket Installation Step 1 Align the quick release extension bracket G 2 1 to the cabinet mounting bracket G 1 screw holes tighten with two round head screws...

Страница 26: ...ten it down Step 2 Insert the latch of the cable management stop bracket D into the quick release extension bracket G 2 1 on the cabinet mounting bracket G 1 Refer to 2 7 2 Step 1 When removing press...

Страница 27: ...t G 1 Refer to 2 7 2 Step 2 When removing press the blue dot to pull out Support Arm C 2 Step 1 Place the support arm C 2 hexagon head screw down to the middle hollow of the support arm C 1 and fasten...

Страница 28: ...head screws K Step 4 Secure the swivel pin E to the chassis mounting bracket F 2 7 4 Cable Management Arm Installation Step 1 Insert the quick release latch B 1 into the right of the cable management...

Страница 29: ...h B 2 into the other side of the cable management arm A When removing press the blue dot to pull out Step 3 Insert the other side of the quick release latch B 2 into the chassis mount bracket F When r...

Страница 30: ...osition Step 3 Tighten the flat head screw I to secure the mounting bracket G 1 to the cabinet For more detailed dynamic installation instructions see the RJ472 Rail CMA Assembly Live Video File Link...

Страница 31: ...S6 Expansion External Downlink MINI SAS HD Connector LED1 LED6 PHY LINK LED LED7 Status LED CN1 Programming Factory only SW1 ID SW LED SW2 System Reset Factory only SW3 Flash burn in test Factory only...

Страница 32: ...bug Mode JD3 Console Smart Mode JC1 MB Fan Control JC2 PMBUS JC3 Front Panel Signal Connector EFN1 Expander Fan connector LED11 12 13 LED11 13 JS1 JS3 PHY LED LED01 Expander Heart Beat LED JS1 JS3 JS1...

Страница 33: ...uctions of frequent use function Please refer to the table of contents to find the topics you are interested in 4 2 Key Features Reliable High Data Rate Support up to 12Gbps SAS 12Gbps support and SAT...

Страница 34: ...ature enables single JBOD to serve multiple hosts Cascading There are cascading ports on the Expander for cascading another JBOD system to expand disk space when more space is required 4 3 Software Ma...

Страница 35: ...o manage the system through terminal console applications such as Tera Term Putty etc Users need to prepare a DB9 RS 232 adapter on host and connect to a serial cable shipped along with the system to...

Страница 36: ...can manage the network setting such as configuring the IP address and enabling disabling services The list command to displays all the Ethernet layer commands the system supports The help command list...

Страница 37: ...for jumping back to the network management layer from expander management layer The or help displays the CLI commands for the SAS Expander Type command to display the current status of the command Ty...

Страница 38: ...the settings to meet the network environment For security reasons we strongly recommend users to change the password immediately before the system is put online Note 4 3 3 1 Telnet The Telnet service...

Страница 39: ...led by default It provides the same level of CLI commands as it is through serial console or Telnet session SSH provides a secure connection between host and the JBOD system It is enabled by default o...

Страница 40: ...37...

Страница 41: ...is the easiest way to manage the JBOD system It is enabled by default on this system Users can simply open the web browser and give the JBOD management IP address in the URL address field to start man...

Страница 42: ...dded with a SNMP agent The InWin JBOD system s management module is implemented by a SNMP agent with v1 and v2c support Users need to configure the same read and write community string in the JBOD sys...

Страница 43: ...onfigure via Web SNMP Manager Any SNMP Managers can be used to manage the system by properly configuring the system settings including IP address read community string and write community string to ma...

Страница 44: ...irmware version through various ways with CLI commands Web GUI and SNMP 4 3 4 1 CLI UART Telnet and SSH Type the version command on mgmt s Layer to display all the version information including Ethern...

Страница 45: ...ress on Web Browser URL address field to gain access to the system After logging in click Version on the left pane to view the system version information on the right pane Scroll down to view all info...

Страница 46: ...their status Please note that the Expander temperature sensors Exp Die is the silicon core temperature and the temperature sensors BPx Sensor x are on the backplanes There are mechanisms communicating...

Страница 47: ...commands on mgmt s layer such as ipaddr gateway netmask etc to view and configure the settings respectively Please be sure to apply the save command so the settings are saved for the next system rebo...

Страница 48: ...show the disk drives status on the system including Bay id Phy id SAS Address Link speed and current status 4 3 7 1 CLI UART Telnet and SSH Type the phyinfox s command on mgmt s expander0 layer to dis...

Страница 49: ...ning feature is enabled the specific wide port is hard coded and designed to join the specific group as the access port of the specific group RJ 212 RJ 316 RJ 224 and RJ 448 support 2 group zoning RJ...

Страница 50: ...the right panel of the page Click Enable to enable zoning and click Disable to disable zoning After configuration is selected click Apply to reset the Expander to take effect Zoning configuration wit...

Страница 51: ...SAS Expander MFG CFG file There are a couple of ways to upgrade the system firmware according to the HW configurations Please note that the upgraded firmware won t take effect until a system reboot No...

Страница 52: ...iently all Expanders including Bridge Expander and internal expanders they are sharing the same firmware and MFG file can be upgraded at the same time when upgrade command is applied and committed To...

Страница 53: ...50 SAS Expander Firmware It s the same as for Management firmware by using the Expander Firmware filename instead in command upgrade tftp_server_ip filename...

Страница 54: ...ys Just simply select the firmware by file browser and click Apply to start All the firmware including Network Management firmware SAS Expander firmware and MFG CFG file apply the same way to upgrade...

Страница 55: ...file browser and click Open to commit The firmware can be management firmware SAS Expander firmware or SAS Expander MFG CFG file The system would intelligently detect the firmware type and upgrade to...

Страница 56: ...53 Web would direct to a page telling the firmware is upgrading After upgrade is done Web will direct to the Login page A system reboot is require to take effect...

Страница 57: ...Web Console Login into Web GUI then click Console on the left panel Then on the right panel select the SAS expander that you would like to apply the command to and fill the command to the rightest sq...

Страница 58: ...assword reboot reboot management board save save configuration to NVRAM service display or set service Telnet SSH WEB SNMP upgrade upgrade management board or expander software useradd add new user ac...

Страница 59: ...main recv sas_addr If sas_addr set then fetch the remote expander s current clock and output the result If sas_addr not specified then get and output the current clock for all expanders in the domain...

Страница 60: ...POST info showpost Show MFG Revision showmfg Show firmware revision rev 5 Compatibility Lists To reach the best performance and avoid system failure InWin strongly recommends users to choose the comp...

Отзывы: