13
2.3.2
Installing the Fan Module
Step 1: Push the fan module back into the slot until it clicks.
Step 2: Secure the thumbscrews in place and tighten.
Step 3: Connect the fan to the backplane.
Step 1
Step 2
2.4
Removing and Installing the PSU+FAN Module
The IW-RJ472-05 hosts dual built-in redundant 1100W PSU
+
FAN modules. Each
module
cage contains one power supply and three fan modules. With this function, the
system is capable of still functioning if one of the modules fail. To replace it, the user
only needs to release the failed module, then insert a functional module.
NOTE:
The
two PSU modules’ output wattage must be the same.
To ensure the stability of use, if the PSU module fails, it is recommended to replace
the PSU with the fan modules together.
2.4.1
Removing the PSU+FAN Module
Step 1: Loosen the thumbscrew of the PSU+FAN module cage at the back.
Step 2: Push down the handle and use the handle to pull out the cage.
Push