![INVT BD-RH1 Series Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/invt/bd-rh1-series/bd-rh1-series_user-manual_2085725005.webp)
5
2.2.2 Conceptual diagram
2.3 Work Modes
Inverter provides multiple work modes based on di
ff
erent requirements.
Work modes:
Self-use
(with PV Power)
Priority: load>battery>grid
This mode applies the area that has low feed-in tari
ff
and high energy price.
The power generated from PV will be used to supply the local loads
firstly, then to charge the battery. The redundant power will export to
the public grid.
Work modes:
Self-use
(without PV Power)
When no PV supplied, battery will discharge for local loads
firstly
,
and grid will supply power when the battery capacity is not enough.
Work modes:
Force time use
Priority: battery>load>grid
(when charging)
Priority: load>battery>grid
(when discharging) this mode applies the
area that has electricity price between peak and valley. User can use o