![INVT BD-RH1 Series Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/invt/bd-rh1-series/bd-rh1-series_user-manual_2085725017.webp)
17
Battery connection diagram
Power Connection Battery
Step1
Choose the 4 AWG wire and strip the cable to 15mm. Select two O-terminals with an
aperture of M8. Insert the stripping line into the O-terminal and clamp it with a
crimping clamp.
Step2.
Cross the battery cable through the battery port. Connect battery cable to
battery terminal.