Part 5. Troubleshooting:
If there is too little fog, the pump makes noise, or if there is no fog at all, disconnect the unit immediately from the
power supply. Do not try to operate the unit further by pressing the activation button on the remote control, as this
can damage the device. Check the liquid level, the external fuse and the remote connection, and make sure that
the wall socket is connected to the power supply. If these points are correct and the unit still does not work, contact
a service technician.
Part 6. Maintenance:
Regularly check the technical safety of the fogging machine. To damage the leads and the housing. Strong dust
deposits, fog residues and dirt reduce the performance and can lead to failure of the device due to overheating. For
longer storage, it is recommended to run the machine at least every 1 to 3 months. Longer periods out of service
can lead to a significant reduction in the service life of the machine. Damage caused by a lack of cleaning of the
device is not covered by the product warranty.
Cleaning.
Disconnect the unit from the mains and allow it to cool down completely before cleaning
.
For external cleaning, use a dry, soft cloth, never use chemicals or water that could enter the unit. Clean the
ventilation openings with a soft brush, cotton swab, a vacuum cleaner or compressed air. Fog machines are
susceptible to clogging due to the thick liquid mist and high evaporation temperature. Therefore, it is recommended
to run a cleaning liquid consisting of 90% distilled water and 10% vinegar after approx. 60 operating hours.
Method:
1. Disconnect the fogging machine from the mains and let it cool down sufficiently.
2. Fully drain the tank.
3. Place the unit in a well-ventilated place.
4. Fill the tank with the specified cleaning fluid.
5. Connect the device to the power supply.
6. Wait until the required operating temperature is reached.
7. Operate the unit in a well-ventilated area with the cleaning liquid until the tank is empty.
8. Cleaning is completed.
Turn the unit off and wait until it has cooled down completely before refilling the mist fluid.
Fuse replacement.
IMPORTANT:
Replace the fuse only with a fuse of the same type and with the same values (printed on the device).
If the fuse is triggered repeatedly, please contact an authorized service center.
Method:
1:
Unplug the power cord from the wall outlet.
2:
Open the fuse holder on the back of the unit with a suitable screwdriver.
3:
Remove the defective fuse from the fuse holder.
4:
Insert the new fuse into the fuse holder.
5:
Replace the fuse holder in the housing.
Maintenance and service work is reserved for the authorized personnel only!
Содержание A-000000-05883
Страница 1: ...Bedienungsanleitung User Manual Stratus1500DMX Dunstnebler Hazer Haze fogger Hazer...
Страница 23: ...22 INVOLIGHT Stratus1500 Stratus1500 INVOLIGHT 1 1 1...
Страница 24: ...23 1 2 20 I 1...
Страница 25: ...24 2 AC220 230 50 INVOLIGHT Stratus1500 http invask ru 3 INVOLIGHT ON 3 Ready to Fog BGV C1 VBG 70 DIN 15560...
Страница 29: ...28 4 7 Function Wireless UP DOWN ON OFF 5 1 2 3 6 1 3 90 10 60 1 2 3 4 5 6 7 8 1 2 3 4 5...
Страница 33: ...32 Stratus1500DMX Bestellnummer A 000000 05883 www involight de...