25
Part 6: Maintenance:
Cleaning and maintenance:
It is imperative that you clean the projector periodically.
Disconnect the device from the mains before performing maintenance work!
The objective lens should be cleaned weekly because fog fluid residues settle very quickly, which significantly reduce
the luminosity of the device
Clean the fan monthly.
The dichroic color filters, the gobo wheel and the inner lenses should be cleaned monthly.
Use a lint-free, damp cloth for cleaning. Under no circumstances use alcohol or any solvents for cleaning!
In order for the bearings of the rotating parts to function properly, they must be lubricated every 6 months. A syringe
with a fine needle should be used for oiling. The amount of oil must not be excessive to prevent the oil from leaking
while rotating. Never bring optical components into contact with greases or oils!
Fuse change.
IMPORTANT NOTICE:
Replace the fuse only with a fuse of the same type and with the same values (printed on the device). If the fuse blows
repeatedly, please contact an authorized service center.
1: Pull the mains plug out of the mains socket and disconnect the power cord from the mains connection on the
device.
2: Open the fuse holder on the back of the device with a suitable screwdriver.
3: Remove the defective fuse from the fuse holder.
4: Insert the new fuse in the fuse holder.
5: Put the fuse holder back in the housing.
Maintenance and service work is reserved for authorized specialist personnel only!