Version 3.07
| Optidrive Eco User Guide |
67
www.invertekdrives.com
11.5.1. 200 – 240 Volt (+/- 10%),1 Phase Input, 3 Phase Output
Frame
Size
Power Rating
Input
Current
Fuse or MCB
(Type B)
Maximum Cable Size
Rated Output
Current
Maximum Motor
Cable Length
kW
HP
A
Non UL
UL
mm
AWG/kcmil
A
m
ft
2
0.75
1
8.6
16
15
8
8
4.3
100
330
2
1.5
1.5
12.9
16
17.5
8
8
7
100
330
2
2.2
3
19.2
25
25
8
8
10.5
100
330
11.5.2. 200 – 240 Volt (+/- 10%), 3 Phase Input, 3 Phase Output
Frame
Size
Power Rating
Input
Current
Fuse or MCB
(Type B)
Maximum Cable Size
Rated Output
Current
Maximum Motor
Cable Length
kW
HP
A
Non UL
UL
mm
AWG/kcmil
A
m
ft
2
0.75
1
3.6
6
6
8
8
4.3
100
330
2
1.5
2
6.5
10
10
8
8
7
100
330
2
2.2
3
9.3
16
15
8
8
10.5
100
330
3
4
5
15.1
25
20
8
8
18
100
330
3
5.5
7.5
20.4
25
25
8
8
24
100
330
4
7.5
10
24.3
32
30
16
5
30
100
330
4
11
15
37.9
50
50
16
5
46
100
330
5
15
20
50.5
63
70
35
2
61
100
330
5
18.5
25
59.9
80
80
35
2
72
100
330
6
22
30
76.7
100
100
150
300MCM
90
100
330
6
30
40
121
160
150
150
300MCM
110
100
330
6A
30
40
97.8
125
125
150
300MCM
110
100
330
6
37
50
159.7
200
200
150
300MCM
150
100
330
6A
37
50
134
200
175
150
300MCM
150
100
330
6
45
50
187.5
250
225
150
300MCM
180
100
330
6B
45
60
163.4
200
200
150
300MCM
180
100
330
6B
55
75
185.9
250
225
150
300MCM
202
100
330
7
55
50
206.5
250
250
150
300MCM
202
100
330
7
75
50
246.3
315
300
150
300MCM
248
100
330
11