Contact an authorised service technician for repair or maintenance of this unit.
The appliance shall be installed in accordance with national wiring regulations.
This appliance is not intended for use by persons(including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Young children should be supervised to ensure that they do not play with the air conditioner.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
Installation work must be performed in accordance with the national wiring standards by
authorised personnel only.
CAUTION
WARNING
Read the follow SAFETY PRECAUTIONS carefully before installation.
Incorrect installation due to ignoring of the instruction will cause harm or damage, and the
seriousness is classified by the following indications.
This symbol indicates the possibility of death or serious injury.
The items to be followed are classified by the symbols:
Symbol will background white denotes item that is PROHIBITED from doing.
CAUTION
This symbol indicates the possibility of injury or damage to property.
WARNING
1) Engage dealer or specialist for installation. If installation done by the user is defective, it will
cause water leakage, electrical shock or fire.
2) Install according to this installation instructions strictly. If installation is defective, it will cause
water leakage, electrical shock or fire.
3) Use the attached accessories parts and specified parts for installation. otherwise, it will cause
the set to fall, water leakage, electrical shock or fire.
4) Install at a strong and firm location which is able to withstand the set s weight. If the strength is
not enough or installation is not properly done, the set will drop and cause injury.
5) For electrical work, follow the local national wiring standard, regulation and this installation
instructions. An independent circuit and single outlet must be used. If electrical circuit capacity
is not enough or defect found in electrical work, it will cause electrical shock or fire.
6) Use the specified cable and connect tightly and clamp the cable so that no external force will
be acted on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the
connection.
7) Wiring routing must be properly arranged so that control board cover is fixed properly. If
control board cover is not fixed perfectly, it will cause heat-up at connection point of terminal,
fire or electrical shock.
8) When carrying out piping connection, take care not to let air substances other than the specified
refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high
pressure in the refrigeration cycle, explosion and injury.
9) Do not modify the length of the power supply cord or use of extension cord, and do not share
the single outlet with other electrical appliances. Otherwise, it will cause fire or electrical
shock.
CAUTION
1) This equipment must be earthed and installed with earth leakage current breaker. It may cause
electrical shock if grounding is not perfect.
2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks
and accumulates at surrounding of the unit, it may cause fire.
3) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect,
water may enter the room and damage the furniture.
4) For the unit adopts auxiliary electric heater, keep at least 1 meter away from the nearest
combustible materials.
SAFETY PRECAUTIONS
SAFETY PRECAUTIONS
Warning .....................................................................................................................................2
Caution ......................................................................................................................................2
INSTALLATION INSTRUCTIONS
Selecting installation place.........................................................................................................3
Accessories ........ .....................................................................................................................3
Indoor & outdoor unit installation drawings ...............................................................................4
TEST RUNNING
Test running ...................... .....................................................................................................14
INDOOR UNIT INSTALLATION
Installation plate mounting..........................................................................................................5
Drill a hole in the wall ........ ......................................................................................................6
Connective pipe installation .......................................................................................................6
Drain piping.................................................................................................................................7
Connect the cable to the indoor unit............................................................................................7
Indoor unit installation..................................................................................................9
OUTDOOR UNIT INSTALLAITON
Outdoor installation precaution ..................................................................................................9
Settlement of outdoor unit ........................................................................................................10
Drain joint installation ...............................................................................................................10
Refrigerant pipe connection .....................................................................................................10
Connect the cable to the outdoor unit .....................................................................................12
Air purging.................................................................................................................................12
,