Refrigerant pipe connection

Oblique

90

Roughness

Burr

Main cause for refrigerant leakage is due to defect 
in the flaring work. Carry out correct flaring work
using the following procedure:

A: Cut the pipes and the cable.

1. Use the piping kit accessory or pipes purchased locally.
2. Measure the distance between the indoor and the 
    outdoor unit.
3. Cut the pipes a little longer than the measured distance.
4. Cut the cable 1.5m longer than the pipe length.

1. Flaring work

Fig.11

Fig.12

Drain joint installation 

Seal

Drain joint

Base pan hole of
outdoor unit

Seal

Drain pipe

(A)

(B)

For the drain joint with the seal(Fig.11 (A)), first
fit  the seal onto the drain  joint, then insert  the  
drain  joint  into the base pan hole of outdoor unit,
 rotate  90

to securely  assemble them. To install 

drain joint as shown in Fig.11 (B), insert  the  drain  
joint into the base pan hole of outdoor unit until it 
remains fixed  with a clicking sound. Connecting 
the drain joint with an extension drain hose (Locally 
purchased), in case of the water draining off the 
outdoor unit during the heating mode.

NOTE: 

In cold areas, do not use a drain hose with

the outdoor unit.(otherwise, drain water may freeze)

NOTE: 

The drain joint is slightly different 

according to the different outdoor unit.

Outdoor unit dimension
          mm(WxHxD)

A(mm)

458

460

B(mm)

250

276

530

590

640

290

333

405

560
549

335
325

549

276

Mounting dimensions

700x540x240

685x430x260

780x540x250

760x590x285

900x860x315

945x810x395

845x700x320
810x558x310

Anchor the outdoor unit with a bolt and nut   10 or 

8 tightly and horizontally on a concrete or rigid mount.

Settlement of outdoor unit

NOTE:

 The outdoor unit you purchase may be like one

of the following. Install the outdoor unit according to the
dimension as indicated in the table below:

A

W

B

D

Air inlet 

Air outlet

Air inlet 

Fig.8

Install the outdoor unit on a rigid base to 
prevent increasing noise level and vibration.
Determine the air outlet direction where the 
discharged air is not blocked. 
In the case that the installation place is exposed 
to strong wind such as a seaside, make sure the 
fan operating properly by putting the unit lengthwise 
along the wall or using a dust or shield plates.
Specially in windy area, install the unit to prevent the 
admission of wind. If need suspending installation, 
the installation  bracket  should accord with technique 
requirement in the installation bracket diagram. 
The installation wall should be solid brick, concrete or 
the same intensity construction, or actions to reinforce, 
damping supporting should be taken. The connection 
between bracket and wall, bracket and the air conditioner 
should be firm, stable and reliable.
Be sure there is no obstacle which block radiating air.

Fig.9

OUTDOOR UNIT INSTALLATION 

Outdoor installation precaution

1. Pass the piping through the hole in the wall.
2. Hook the indoor unit onto the upper portion 
    of installation plate(Engage the indoor unit with 
    the upper edge of the installation plate). Ensure 
    the hooks are properly seated on the installation 
    plate by moving it in left and right.
3. Piping can easily be made  by lifting the indoor 
    unit with a cushioning material between the 
    indoor unit and the wall. Get it out after finish 
    piping. When use a wall embedded pipe, the 
    indoor unit can be moved to the left or right for 
    30~50mm(model dependent), which offers 
    sufficient space to arrange the pipes and ensure 
    the indoor unit fully close to the wall after installation. 
4. Press the lower left and right side of the unit 
    against the installation plate until hooks 
    engages with the their slots.

Indoor unit installation

Strong 
wind

Strong 
wind

Barrier 

Incorrect

Wall embedded pipe

Move to left or right

150mm

30~50mm

30~50mm

Correct

OUTDOOR UNIT INSTALLATION 

OUTDOOR UNIT INSTALLATION 

Fig.10

NOTE:

 Connective pipe length will affect the 

capacity and energy efficiency of the unit. The 
nominal efficiency is tested basing on the pipe 
length of 5 meters. Consult the technicians to
purchase proper size connective pipe for your
machine..

O

30

Содержание V4MVI-09WFR/V4MVO-09

Страница 1: ...itioning system For correct use of this unit please read this manual carefully and keep it for future reference V4MVI 09WFR V4MVO 09 V4MVI 12WFR V4MVO 12 V4MVI 18WFR V4MVO 18 V4MVI 24WFR V4MVO 24 English Installation Manual Wall Mounted Unit ...

Страница 2: ...An independent circuit and single outlet must be used If electrical circuit capacity is not enough or defect found in electrical work it will cause electrical shock or fire 6 Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on the terminal If connection or fixing is not perfect it will cause heat up or fire at the connection 7 Wiring routing m...

Страница 3: ...s Do not place any obstacles which may cause a short circuit of the discharged air Select a location which avoids causing a nuisance to neighbours from noise and air emissions from device Select a location which is sufficiently well ventilated Never cover the air inlets and outlets The location must be sufficientlyfirm for installation and the prevention of vibrations There must be no risk present...

Страница 4: ...rom rear of the indoor unit is gathered in ponding box and is piped out of room Do not put anything else in the box Fig 4 1 For the left hand and right hand piping remove the pipe cover from the side panel 2 For the right back and left back piping install the piping as shown NOTE 3 Attach the drain hose to the underside of the refrigerant pipes with adhesive viny tape 4 Wrap the refrigerant pipes ...

Страница 5: ...Max Current ofthe unit should be installed in power circuit Ensurethe air conditioner is groundedwell 4 The appliance shall beinstalled in accordance with nationalwiring regulations Do not operate your air conditioner in a wet roomsuch as a bathroom orlaundry room 5 An all poledisconnection device which has atleast 3mm clearances in allpoles and have a leakage current that may exceed10mA the resid...

Страница 6: ...ion Determine the air outlet direction where the discharged air is not blocked In the case that the installation place is exposed to strong wind such as a seaside make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates Specially in windy area install the unit to prevent the admission of wind If need suspending installation the installatio...

Страница 7: ...wn in Fig 16 17 2 Tightening Connection Excessive torque can break nut depending on installation conditions Indoor unit tubing Flare nut Pipings Fig 16 Outer diam mm A mm Max Min 6 35 1 3 0 7 9 52 1 6 1 0 12 7 1 8 1 0 12 7 16 1 8 2 2 1 0 2 0 Outer diam Tightening torque N cm Additional tightening torque N cm 6 35 12 7 16 9 52 1500 153kgf cm 1600 163kgf cm 3500 357kgf cm 3600 367kgf cm 2500 255kgf ...

Страница 8: ...lect the AUTO or COOL the unit will operate under Forced AUTOor COOL mode see User Manual for details 4 The testoperation should last about 30 minutes When relocate the unit to another place perform evacuation using vacuum pump Make sure the refrigerant added into the air conditioner is liquid form in any case Not applicable to the units adopt freon R22 Open the valve stem until it hits against th...

Отзывы: