INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Read completely, then follow step by step.

Fig.1

E

F

D

2.3m or more 

Air filter

12cm or more

12cm or mote

15cm or more

A

B

C

C

A

60cm

 or m

ore

6

0

cm

 o

m

o

re

30cm

 or m

ore

Air Outlet

30cm

 or m

ore

Wrapping tape(wrap the 
insulation pipe with the tape 
from bottom to top)

Allow two of A, B and C 
directions to be free 
from obstructions.

Where there is a danger of the
unit falling, use foot bolts to 
fix.

B

200c

m or

 mor

e

Additional drain pipe

Accessories

  ( C)

TEMP

AUTO 
COOL
DRY
HEAT

FAN
HIGH
MED
LOW

MODE

FAN SPEED

TIMER ON

SLEEP

ON/OFF

TIMER OFF

        AIR 
 DIRECTION

RESET LOCK

SET TEMPERATURE

        SWING

        LED
    DISPLAY

        TURBO

There should not be any heat source, inflammable gas or stream near the unit.
There should not be any obstacles blocking the air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the restrictions on installation specified in the indoor unit installation drawings are met.
Select a location which is firm enough for installation so that the device is not subjected to 
vibrations.
The device should beinstalled at a distance of at least 1m from all other electrical devices and
installations, e.g. TV, radio,computer, etc.
There should not be any direct sunlight. If unavoidable, sunlight prevention should be taken 
into consideration.

Indoor  unit

Outdoor  unit

If an awning is built over the unit to prevent direct sunsight or rain,be careful that heat 
radiation from the condenser is not obstructed.
There should not be any animal or plant which could be affected by hot air discharged.
Make sure that  there is sufficient space as specified in the installation drawings.
Do not place any obstacles which may cause a short circuit of the discharged air.
Select a location which avoids causing a nuisance to neighbours from noise and air emissions
from device.
Select a location which is sufficiently well ventilated.
Never cover the air inlets and outlets.
The location must be sufficiently firm for installation and the prevention of vibrations.
There must be no risk presented by combustible gas or gas escaping as a result of corrosion.
Avoid a location where there is a high salt content.
Avoid a location which is heavily exposed to dust.
Avoid a location to which the general public have access.

Selecting installation place

Installation plate

Seal 

Drain joint

Ower s manual

Installation manual

Remote controller
illustration

Clip Anchor

Clip Anchor(5)

Mounting plate fixing 
screw ST3.9x25

Installation plate fixing 
screw ST3.9x25(5)

Remote controller 

Remote 
controller 

Fixing screw for remote 
controller holder 
ST2.9X10

Fixing screw for
remote controller 
holder ST2.9X10

Air freshening filter
(used to install on 
  Air filter)

                     1
         

(for cooling & heating 

            models only)

5

5

1

1

1

1

1

2

1

1

2

Use the supplied installation accessories as required. The items necessary to install
this air conditioner are not included must be purchased separately.

Remote controller holder

Connective pipe assembly

Dry battery AAA.LR03

Indoor unit

NOTE

:

optional 
parts

Indoor & outdoor unit installation drawings

The mounting plate should be installed on a wall 
which can support the weight of the indoor unit.

Before screwing the remote 
controller holder to the wall,
make sure that control signals
are properly received by
indoor unit.

In sites with poor drainage, use
block bases for outdoor unit.
Adjust its height until the unit
is leveled. Otherwise, water
leakage or pooling of water 
may occur. 

A

I

J

K

L

M

N

B

C

D

E

F

G

H

H

1

,

Install the air freshening
filter at the back of air filter

NOTE: 

Appearance of outdoor unit and indoor unit may differ from some models.

             The actual shape shall prevail. 

Содержание V4MVI-09WFR/V4MVO-09

Страница 1: ...itioning system For correct use of this unit please read this manual carefully and keep it for future reference V4MVI 09WFR V4MVO 09 V4MVI 12WFR V4MVO 12 V4MVI 18WFR V4MVO 18 V4MVI 24WFR V4MVO 24 English Installation Manual Wall Mounted Unit ...

Страница 2: ...An independent circuit and single outlet must be used If electrical circuit capacity is not enough or defect found in electrical work it will cause electrical shock or fire 6 Use the specified cable and connect tightly and clamp the cable so that no external force will be acted on the terminal If connection or fixing is not perfect it will cause heat up or fire at the connection 7 Wiring routing m...

Страница 3: ...s Do not place any obstacles which may cause a short circuit of the discharged air Select a location which avoids causing a nuisance to neighbours from noise and air emissions from device Select a location which is sufficiently well ventilated Never cover the air inlets and outlets The location must be sufficientlyfirm for installation and the prevention of vibrations There must be no risk present...

Страница 4: ...rom rear of the indoor unit is gathered in ponding box and is piped out of room Do not put anything else in the box Fig 4 1 For the left hand and right hand piping remove the pipe cover from the side panel 2 For the right back and left back piping install the piping as shown NOTE 3 Attach the drain hose to the underside of the refrigerant pipes with adhesive viny tape 4 Wrap the refrigerant pipes ...

Страница 5: ...Max Current ofthe unit should be installed in power circuit Ensurethe air conditioner is groundedwell 4 The appliance shall beinstalled in accordance with nationalwiring regulations Do not operate your air conditioner in a wet roomsuch as a bathroom orlaundry room 5 An all poledisconnection device which has atleast 3mm clearances in allpoles and have a leakage current that may exceed10mA the resid...

Страница 6: ...ion Determine the air outlet direction where the discharged air is not blocked In the case that the installation place is exposed to strong wind such as a seaside make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates Specially in windy area install the unit to prevent the admission of wind If need suspending installation the installatio...

Страница 7: ...wn in Fig 16 17 2 Tightening Connection Excessive torque can break nut depending on installation conditions Indoor unit tubing Flare nut Pipings Fig 16 Outer diam mm A mm Max Min 6 35 1 3 0 7 9 52 1 6 1 0 12 7 1 8 1 0 12 7 16 1 8 2 2 1 0 2 0 Outer diam Tightening torque N cm Additional tightening torque N cm 6 35 12 7 16 9 52 1500 153kgf cm 1600 163kgf cm 3500 357kgf cm 3600 367kgf cm 2500 255kgf ...

Страница 8: ...lect the AUTO or COOL the unit will operate under Forced AUTOor COOL mode see User Manual for details 4 The testoperation should last about 30 minutes When relocate the unit to another place perform evacuation using vacuum pump Make sure the refrigerant added into the air conditioner is liquid form in any case Not applicable to the units adopt freon R22 Open the valve stem until it hits against th...

Отзывы: