![inVENTer ZR10-D Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/inventer/zr10-d/zr10-d_installation-and-operating-instructions-manual_2083882041.webp)
41
ZR10-D controller
•
Installation and operating instructions
7.3
Setting the sleep timer mode (ZR10-D-Flat controller only)
noTe
The sleep timer mode is only selectable with the ZR10-D-Flat controller. In zero position (power
stage 0) the ZR10-D-Flat controller switches off the fan at irst. After 60 minutes the ventilation sys
-
tem restarts at 17 % of the maximum power in the heat recovery mode (see section 2.2: Function
‒
Sleep timer mode).
Requirements:
Heat recovery mode / ventilation mode is set.
► Turn rotary button (3) at finger guide (2) from set
operating mode to zero position (1).
Ö
LED
is extinguished
.
2
1
3
Ö
The sleep timer mode is set.
7.4
Setting the OFF mode (ZR10-D-Standard controller only)
Requirements:
Heat recovery mode / ventilation mode is set.
► Turn rotary button (3) at finger guide (2) from set
operating mode to zero position (1).
Ö
LED is extinguished.
Ö
The ventilator is switched off.
2
1
3
Ö
The OFF mode is set.