16
ZR10-D controller
•
Installation and operating instructions
6
assembly and installation
6.1
making wall opening / boreholes
Danger
flush mounted cables.
Short circuit causes electric shock!
► Locate wall opening / boreholes outside of lush mounted cables.
caUTIon
falling masonry while making a wall opening.
Can result in material losses and / or loor covering!
► Provide protection against falling masonry on the loor covering.
► Remove objects from immediate vicinity of the wall opening in the interior.
Making wall opening for lush mounted dual box
Requirements:
Masonry must be dry and load-bearing.
Plasterboard is inished.
Avoid lintels when drilling wall opening.
►
Fit two wall openings (Ø 68 mm) f
or the lush
mounted dual box in the interior wall
.
►
Ensure the distance of the centres of the
wall openings is 71 mm.
Ø 68
71
►
Remove ridges (dashed line) between the
wall openings.
Wall opening for lush mounted dual box is ready.
assembly anD InsTallaTIon