background image

28

Pulsar extractor fan 

 Installation and operating instructions

A pulsar can be configured via multiple mobile devices.

This is subject to the following requirements:
•  The Pulsar must be within range of the mobile device 

(max. 10 m distance).

•  The Bluetooth Smart connection must be enabled.
•  The pulsar must be displayed as active on the mobile 

device.

•  At any given time, the Pulsar can only be operated from 

one mobile device. Simultaneous control of the same 
Pulsar from multiple mobile devices is not possible. 
In this case, only the first device to establish a connec-
tion is able to control the Pulsar.

You can find out more about the possibilities offered by 
inVENTer Mobile and download the app directly here:  
www.inventer.de

Operation

7.1  Functional scope

Pulsar is operated and controlled via the inVENTer Mobile 
app. Without app control, only the factory settings are 
available. 

The app provides the following additional functions for your 
Pulsar:

Configuration of:
•  Fan speed (depending on sensor) 

optionally in per cent, rpm or litres per second

•  Sensitivity of the humidity sensor with three levels: 

Low – Medium – High 
Setpoint

•  Sensitivity of the light sensor with three levels: 

Low – Medium – High 
Setpoint

•  Run-on time between 5 and 60 minutes
•  Power-on delay between 5 and 10 minutes
•  Boost function
•  Intelligent pause function: 

Once per day, for a freely selectable period of time you 
can set your Pulsar to OFF (only if no continuous venti-
lation is set) or to run with minimum power (continuous 
ventilation)

•  Interval mode: When interval mode is activated, your Pul-

sar runs once every 12 hours for 30, 60 or 90 minutes at 
maximum speed.

•  Continuous ventilation
•  Temperature settings in a range from 15 to 35 °C when 

used as a wall-vent fan

OPERATION

Содержание Pulsar

Страница 1: ...Pulsar extractor fan Installation and operating instructions ...

Страница 2: ...ed for compliance with the described hardware and software Nevertheless deviations may still occur therefore no guarantee of compliance can be provided This documentation describes the functionality of the standard scope The documentation does not purport to cover all details on all types of the product and cannot cover every conceivable scenario for installation assembly operation cleaning and ma...

Страница 3: ... 2 Electrical connection 12 V DC 14 5 Installation 16 5 1 Creating the wall opening and installing the wall sleeve 16 5 2 Installing the PSU optional 18 5 3 Inserting and connecting the Pulsar extractor fan 20 5 2 Installing the fan casing s cover and fan unit 25 6 Commissioning 27 7 Operation 28 7 1 Functional scope 28 7 2 Status LED 29 8 Cleaning and maintenance 30 9 Specifications 32 10 Deliver...

Страница 4: ... an installation sequence lists the necessary tools for the described work Action required This requires you to perform a specific action Check the results This requires you to check the results of the action you have performed The illsustrations always show the interior wall 1 2 Safety instructions These installation and operating instructions are part of the ventilation unit and must be permanen...

Страница 5: ...n the meaning of the safety notices in this documentation are persons who are authorised to install put it into operation and identify equipment systems and circuits in accordance with established safety proce dures General safety regulations Always observe the relevant standards regulations and guidelines when working The Pulsar extractor fan is designed for fixed installation with permanent cabl...

Страница 6: ... does not interfere with other ventilation processes and that its functioning is not affected by them it must always be installed in its own wall sleeve This must not contain any obstructions or other objects that interfere with the airflow In order to prevent the accumulation of condensate in winter in wall sleeves they must be insulated at the places where they run through unheated areas such as...

Страница 7: ... Mobile app If required the Pulsar extractor fan can also be used as a wall vent fan for ventilation and heating of adjacent areas e g unheated rooms The extractor fan turns on when the selected temperature limit is exceeded It switches off again when the room temperature falls back within the selected range The extractor fan is controlled and configured using the inVENTer Mobile app You can downl...

Страница 8: ... area 0 Install light switch switch pushbutton outside protection areas 0 to 2 Area 2 Area 1 Area 0 2250 600 2 1 Positioning in the air flow of the room Install the Pulsar extractor fan within the air flow of the room This will ensure optimal humidity extraction and reliable detection of the humidity by the humidity sensor Figure 2 Overview of electrical protection areas in bathrooms Figure 3 Idea...

Страница 9: ...ll thickness 115 Borehole for suspended ceiling Wall thickness 105 Borehole for flush mounted box for PSU 66 68 Borehole for flush mounted plaster board box for PSU 61 68 Installation elements Pulsar extractor fan 81 177 Wall sleeve DN 100 Wall thickness 100 Power supply unit PSU 32 54 1 Wall sleeves are available in the aV100 wall installation set including weather protection hood from inVENTer G...

Страница 10: ...rical installations disconnect all affected equipment from the power supply Do not lay or connect live cables The connection must only be performed by qualified and trained personnel DANGER Ingress of water into the Pulsar extractor fan or its components power source Electric shock and overheating due to short circuit 230V 50Hz Install Pulsar outside protection area 0 Install Pulsar s power source...

Страница 11: ...30 V AC Wiring diagrams for 230 V AC connection The connection of the extractor fan depends on the desired functions Ensure that you connect the extractor fan correctly and select the correct presets for your desired functions during commissioning ELECTRICAL CONNECTION ELECTRICAL CONNECTION 1 Cable inlet for power cable 2 Cable feed through on Casing 3 Connection terminal for power cable 230 V AC ...

Страница 12: ...ntilation of adjacent rooms The extractor fan is switched on off based on the temperature the light and humidity sensors are inactive 4 Switch controlled without run on function This setting must be selected via the inVENTer Mobile app The extractor fan is switched on and off by means of a manual external S switch The sensors are deactivated When the fan is switched off at the external S switch th...

Страница 13: ...C 100 240 V DC 12 V S1 M T L N S Figure 6 Wiring diagram for Pulsar extractor fan 230 V AC with sensors activated Figure 7 Wiring diagram for Pulsar extractor fan 230 V AC switch controlled without run on function Figure 8 Wiring diagram for Pulsar extractor fan 230 V AC switch controlled with run on function ELECTRICAL CONNECTION ...

Страница 14: ...230 V 50 Hz Before working on electrical installations disconnect all affected equipment from the power supply Do not connect the power supply unit under voltage The connection must only be performed by qualified and trained personnel DANGER Ingress of water into the power supply unit Electric shock and overheating due to short circuit 230V 50Hz Install power supply unit outside protection areas 0...

Страница 15: ...etting must be selected via the inVENTer Mobile app Continuous ventilation with a flow rate of 30 m h Increases the fan power with elevated humidity or due to lighting changes Figure 10 Wiring diagram for flush mounted PSU NT16 and Pulsar extractor fan 12 V DC Versions 1 to 3 sensor controlled and use as wall vent fan This setting must be selected via the inVENTer Mobile app The extractor fan is s...

Страница 16: ...sonry Remove objects from the immediate vicinity Milling drill with ø 115 mm wall sleeve e g from aV100 wall installation set Requirements The masonry must be dry and in a load bearing condition There must be no load bearing elements at the location of the planned borehole plaster or wall slot NOTICE Accumulation of condensate in the wall sleeve Damage to the exterior wall and masonry Create the w...

Страница 17: ...instructions for aV100 wall installation set OR Install another wall sleeve DN 100 Ensure that the new or existing wall sleeve does not end flush to the interior wall It is installed with an inner distance of 5 mm inside the wall Ensure that an appropriate back draught shutter is provided and installed on site Lay the power cable 3 wire to the wall opening for the wall sleeve Ensure that the cable...

Страница 18: ...trical connection A power supply unit as well as a flush mounted plasterboard box can be ordered as optional accessories The installation process described below uses the example of a flush mounted box Installation in a flush mounted plasterboard box follows the same principle Milling drill with ø 68 mm insulating terminal filler for plastering in the box Requirements The masonry must be dry and i...

Страница 19: ...ed box Insert the flush mounted box into the wall opening Fill the space between the interior wall and the flush mounted box with a suitable filler Ö Ö The flush mounted box for the power supply unit has been fitted Connect the power cable 230 V AC to the PSU s input terminals blue brown using one of the enclosed lustre terminals Connect the fan operating voltage cable 12 V DC to the output cable ...

Страница 20: ...able 230 V 50 Hz DC 12 V is laid Grip the fan unit from behind with both hands Pull the fan unit out of the fan casing from the front Ensure that you hold the fan unit firmly so that it does not fall to the ground when released Carefully remove the rubber seal from the back of the fan casing Ensure that you pull off the rubber seal beginning on the opposite side of the integrated switch Remove the...

Страница 21: ...a screw driver to press in the lock button red arrow on the fan casing Loosen the cover of the fan casing Reattach the rubber seal to the back of the fan casing Ensure that you first place the switch red arrow carefully into the opening provided Then press the rubber seal firmly into the fan casing s base plate INSTALLATION ...

Страница 22: ...from the interior Make sure that the word TOP is pointing upwards Level the fan casing using a spirit level To do this place the spirit level against the support points on the fan casing red arrows Mark the 3 mounting holes blue areas Remove the casing from the wall sleeve and drill the holes R75 30 65 95 DANGER Exposed electrical components Electric shock and injury due to live components 230 V 5...

Страница 23: ...ls the extractor fan to the interior wall 2 1 NOTICE Over shortened cable Cable cannot be reconnected after disassembly for maintenance work Do not excessively shorten the cable Shorten the voltage cable so that it reaches the respective connection terminal red arrows 230 V AC 3 pole connec tion terminal 12 V DC 2 pole connection terminal Take care not to lay the voltage cable over the PCB Ensure ...

Страница 24: ... and operating instructions Connect the shortened voltage cable in accordance with the wiring diagram to the terminal block AC 230 V T Ls N L Ö Ö The Pulsar extractor fan is inserted and the voltage cable is connected DC 12 V INSTALLATION ...

Страница 25: ...er circuit Snap the hook on the bottom of the fan casing s base plate into the hole red arrow on the lower side of the fan casing s cover Make sure that the guides for the fan unit are pointing upwards Press the upper part of the fan casing s cover onto the bracket red arrow on the fan casing s base plate Ensure that the lock button red arrow clicks into place between the guides for the fan unit I...

Страница 26: ...e fan are not damaged Ö Ö A clearly audible click confirms that the fan unit is installed correctly Ensure that the fan can rotate freely before switching it on Connect the Pulsar extractor fan to the power supply Switch on the device 230 V AC The switch is located on the left side of the fan casing Push it up into position 1 12 V DC The fan runs when connected to the power supply if switch contro...

Страница 27: ...ality Mobile device with Android or iOS operating system Bluetooth Smart Advice Disable the automatic pairing function before setting up your Pulsar The operating systems and corresponding app versions are continually updated Additional information is available on our website www inventer com and directly from the App Store iOS or Play Store Android Activating the inVENTer Mobile app Step 1 Downlo...

Страница 28: ...s operated and controlled via the inVENTer Mobile app Without app control only the factory settings are available The app provides the following additional functions for your Pulsar Configuration of Fan speed depending on sensor optionally in per cent rpm or litres per second Sensitivity of the humidity sensor with three levels Low Medium High Setpoint Sensitivity of the light sensor with three le...

Страница 29: ... fan indi cates that an active Bluetooth Smart connection to a mobile device has been established Please note that the blue LED must be illuminated before you can operate or configure the Pulsar extractor fan Red LED illuminated The red LED is a fault indicator A red LED on the fan unit of the Pulsar extractor fan indicates a power failure when the intelligent pause function is configured A reset ...

Страница 30: ...Pulsar extractor fan is virtually maintenance free Any necessary cleaning or maintenance work can be carried out by the user by following these instructions The maintenance tasks and intervals listed here are recommended by inVENTer GmbH to maintain the functionality and performance of the Pulsar extractor fan Depending on requirements and or air quality your personal maintenance plan may deviate ...

Страница 31: ...cloth Make sure that the fan is cleaned directly in the fan unit it must not be removed Carefully insert the fan unit with the feet first into the two guides red arrows on the fan casing Ensure that the fan unit is not tilted during installation This ensures that the feet and the fan are not damaged Ö Ö A clearly audible click confirms that the fan unit is installed correctly Grip the fan unit fro...

Страница 32: ...ng m h 110 Power consumption W 4 Noise emission rated dB A 17 20 Ambient temperature C 5 50 Supply air Free from aggressive gases dust and oils Diameter x depth mm 177 x 81 Weight g 400 Flush mounted switching PSU NT16 Feature Value Protection class II Type of protection IP20 Input voltage V AC Hz 230 50 Output voltage V DC 12 Power output W 12 Operating temperature C 5 50 Diameter x height mm 54 ...

Страница 33: ...essories Component Order number aV100 wall installation set 1001 0159 Flush mounted switching PSU NT16 1003 0094 Flush mounted box 60x66 3002 0244 Flush mounted plasterboard box 61x68 1003 0084 Air flow characteristic of Pulsar extractor fan Luftvolumenstrom m h Druckdifferenz Pa SPECIFICATIONS Pressure difference Pa Air flow m h ...

Страница 34: ... your country The warranty refers to the defect free condition of the product at the time of purchase and covers all defects that were present at the time of purchase Failure to observe the intended use will invalidate all warranty claims Manufacturer guarantee InVENTer GmbH provides a five year guarantee for the Pulsar extractor fan This covers premature product wear Further information about the...

Страница 35: ...MBH 2016 17 ALL INFORMATION IS SUPPLIED WITHOUT GUARANTEE SUBJECT TO MODIFICATIONS NO LIABILITY IS ACCEPTED FOR PRINTING ERRORS COMPANY DETAILS Disposal Dispose of the product in compliance with the applicable national regulations The products described in these installation and operating instructions are largely recyclable due to their low pollutant processing Contact an electronic appliance disp...

Страница 36: ...2017 inVENTer GmbH Ortsstraße 4a D 07751 Löberschütz 49 0 36427 211 0 49 0 36427 211 113 Email info inventer de PIN code serial number Important To activate the inVENTer Mobile app enter the PIN code or scan it with your phone You can also find your specific PIN code on the right foot of the fan unit ...

Отзывы: