11.1.2 Error Codes And Diagnostic Codes
Flash code
Fault
Consequence for the
scooter
Comments
1
Batteries must be
charged
Continues to drive
•
The batteries are discharged. Charge the batteries as
soon as possible.
2
Battery voltage too low
Stops driving
•
The batteries are depleted. Charge batteries.
•
If you switch the scooter off for a few minutes, the
batteries can often recuperate to such a stage that a
short journey is still possible. You should only do this
in an emergency, however, because this causes the
batteries to become excessively discharged.
3
Battery voltage too high
Stops driving
•
The battery voltage is too high. If the battery charger
is connected, disconnect it from the scooter.
•
The electronic system charges the batteries when
running downhill and when braking. This fault is
caused when the battery voltage becomes too high
during this process. Switch the scooter off and on
again.
4
Power time exceeded
Stops driving
•
The maximum current was exceeded over too long a
period, probably because the motor was overloaded
or has been working against an immovable resistance.
Switch the scooter off, wait a few minutes and then
switch on again.
•
The electronic system has determined a motor
short-circuit. Check the wiring harness for short-circuit
and check the motor.
•
Contact your Invacare provider.