Invacare
®
- Kite
SERVICE MANUAL
123
CAUTION!
Property damage can result if the counter is wrongly connected. If the plus and minus
wires are connected the wrong way, it will damage the electronic components of the
operating hours counter.
•
Make sure the cable is connected correctly.
•
•
Assembly of the operating hours counter is
carried out in the reverse order.
•
Protect the cable from tension using a cable
tie (3).
•
Connect the plug of the blue wire (-) to the
plug contact of the operating hours counter
which is marked with a "2".
•
The blue wire is additionally marked with a
minus symbol.
•
Connect the plug of the brown wire (+) to the
plug contact of the operating hours counter
which is marked with a "1".
•
The blue wire is additionally marked with a
sleeve, which has a plus symbol on it.
•
Assemble all remaining parts again in
reverse order.