EN-V233 – 5009 – AB – 07-0106-EN (EEN-REC4)
Real Time Receiver and RW Installation and use Page 6 / 11
LED FEATURE
Solid Light
Real Time
Flashes
RW
: Check cabling Device not detected
☺
:
Cabling OK Device detected
STATE
M
EANING
A)
LED
IN
R
EAL TIME MODE
Flashing for 1 to 2 sec
☺
☺
☺
☺
Power supply on
After switch of switch 6: delete rolling code.
Permanently ON
Normal operation in real time mode:
Diagnostic displays “HF” on 03-0101-EN control unit
Goes off for 1 second
HF transmission from 868Mhz Intratone remote
control received properly.
Twinkling
Error on data bus: Check D+/D- terminals
Permanently OFF
No power to receiver: Check +/- terminals
B)
LED
IN
RW
(R
EAD
/W
RITE
)
MODE
Flashing for 1 to 2 sec
☺
☺
☺
☺
Power supply on
After switch of switch 6: delete rolling code.
1 flash every 3 sec
New device in RW (Read/Write) mode:
A programmed remote control has not yet been
used with the receiver.
If switch 6 is set to ON (see page 7), all Intratone
remote controls, programmed or not, are authorized.
2 flashes every 3 seconds
Device operating in RW mode:
The receiver will work with remote controls
programmed for residents on the website with a
USB programmer.
Access control is active: only authorized residents
may enter with their remote controls.
“Pass Keys” do not work in this mode.
Constant slow flashing
Pass option activated in RW mode:
(see section on device configuration).
Lighted for 1 second
Receiving an HF transmission from a remote control.
2-3 seconds quick flashes
Detecting a new remote control
10 seconds quick flashes
Receiver launching
Twinkling
Memory invalid or missing
Permanently OFF
No power to receiver: Check +/- terminals