EN-V233 – 5009 – AB – 07-0106-EN (EEN-REC4)
Real Time Receiver and RW Installation and use Page 7 / 11
SWITCHES
Always position switch 6 to OFF
A)
S
WITCHES IN
R
EAL
T
IME
Timing of relay openings
“INPUT” and “OUTPUT”
Other switches
S 1
S 2
S 3
Opening
Switch
Details
OFF
OFF
OFF
0.2 sec
S6
SECURING ACCESS:
Always set to OFF.
Note: Restarting has no effect on Real Time
mode.
ON
OFF
OFF
01 sec
OFF
ON
OFF
03 sec
ON
ON
OFF
05 sec*
OFF
OFF
ON
10 sec
S4
Not used in this mode!
ON
OFF
ON
15 sec
OFF
ON
ON
30 sec
ON
ON
ON
60 sec
*05 sec or timing defined by control unit.
B)
S
WITCHES IN
RW
MODE
Timing of relay
openings
“INPUT” and “OUTPUT”
Which button should be used on the remote
control?
S 1
S 2
S 3
Opening
S 4
Using buttons
OFF
OFF
OFF
0.2 sec
OFF
- I and II on 4 button
remote controls.
- Left and Right for
2 button remote controls
ON
OFF
OFF
01 sec
OFF
ON
OFF
03 sec
ON
ON
OFF
03 sec
OFF
OFF
ON
10 sec
ON
- III and IIII on 4 button
remote controls.
- 2 button remote controls
do not work in this mode
ON
OFF
ON
15 sec
OFF
ON
ON
30 sec
ON
ON
ON
60 sec
C)
S
WITCHES
5
AND
6
Switch 5: Function that “authorizes the use of saved Dip Switches”
S5
ON
Activates Dip Switch opening.
S5
OFF
Prevents Dip Switch opening.
Switch no.6: RAZ and Secure Features
1)SECURING ACCESS: Always position switch 6 to OFF
2) Resetting the 07-0106-EN (EEN-REC 4) receiver in “read/write” mode:
Following a reset, all Intratone RW remote controls will be deleted from the memory.
Remember to set S6 to OFF
The receiver is reset to its factory settings.
To reset the receiver:
Click switch 6 (the LED lights up) and wait until the LED begins to flash.
Repeat this action twice until the LED flashes quickly.
As soon as the LED flashes once every 3 seconds, the reset is complete and the 07-
0106-EN (EEN-REC4) receiver has been returned to factory settings and RW mode.
Turn the switch back to OFF.