background image

EN-V233 – 5009 – AB – 07-0106-EN (EEN-REC4)  
Real Time Receiver and RW Installation and use                                                 Page 3 / 11 

DIMENSIONS AND FITTING 

 

 

RW memory 

(removable) 

LED Detection  

of Dip Switches 

Cable Tie 

Waterproof seal 

Switches  

for settings 

Wall bracket 

Dip Switch detector 

button 

Waterproof HF eco receiver 
Real time or RW modes 

Ref: HREC4 canon number :

 

POWER  BUS  Input Output 

T

IM

D

EL

A

Y

 

R

EL

A

Y

 

R

W

-b

u

tt

o

n

s

  

1

-2

/3

-4

 

R

e

s

e

Содержание 07-0106-EN

Страница 1: ...ratone range s 868Mhz remote controls Anti Passback is not available with this model see EEN REC2 or EEN REC2 RW A REAL TIME MODE In real time mode this receiver MUST be registered on the Intratone website using one of the solutions listed below GPRS module 3G module Visio 2 panel Depending upon your needs you may add an Intratone 03 0101 EN or 03 0102 EN control unit B RW MODE READ WRITE This rec...

Страница 2: ...CHING RW READ WRITE MODE 5 LED FEATURE 6 A LED IN REAL TIME MODE 6 B LED IN RW READ WRITE MODE 6 SWITCHES 7 A SWITCHES IN REAL TIME 7 B SWITCHES IN RW MODE 7 C SWITCHES 5 AND 6 7 DIP SWITCHES FEATURE 8 A CONCEPT 8 B HOW DOES IT WORK 8 C SAVING DIP SWITCH CODES 8 D OPENING WITH DIP SWITCH CODES 8 E RESET DIP SWITCH CODES RAZ 8 INSTALLATION PRECAUTIONS 9 ROLLING CODE OPERATION 9 STANDARDS 10 A EC ST...

Страница 3: ...IMENSIONS AND FITTING RW memory removable LED Detection of Dip Switches Cable Tie Waterproof seal Switches for settings Wall bracket Dip Switch detector button Waterproof HF eco receiver Real time or RW modes Ref HREC4 canon number POWER BUS Input Output TIME DELAY RELAY RW buttons 1 2 3 4 Reset ...

Страница 4: ...C DC 100 mA 2 1 AER With 868Mhz aerial NOT SUPPLIED Optional assembly Core Braid WIRING With wire Assembled in factory Dry contact to Managed devices 2 Relays 1A with 24V 5A with 12V To D D of GPRS 3G module and or of control unit 03 0101 EN EEN CEN12 03 0102 EN EEN CIC12 REAL TIME Real time cabling 0 8 Max 200m OR ...

Страница 5: ...e an account create an account button if logging on for the first time Create a residence and then a 07 0106 EN EEN REC4 access by entering the serial number for receiver 07 0106 EN EEN REC4 You will then be able to program the remote controls that you will allocate to residents The remote controls will automatically open the doors controlled by the receiver The first control will launch the recei...

Страница 6: ...itch of switch 6 delete rolling code 1 flash every 3 sec New device in RW Read Write mode A programmed remote control has not yet been used with the receiver If switch 6 is set to ON see page 7 all Intratone remote controls programmed or not are authorized 2 flashes every 3 seconds Device operating in RW mode The receiver will work with remote controls programmed for residents on the website with ...

Страница 7: ...OFF OFF 01 sec OFF ON OFF 03 sec ON ON OFF 03 sec OFF OFF ON 10 sec ON III and IIII on 4 button remote controls 2 button remote controls do not work in this mode ON OFF ON 15 sec OFF ON ON 30 sec ON ON ON 60 sec C SWITCHES 5 AND 6 Switch 5 Function that authorizes the use of saved Dip Switches S5 ON Activates Dip Switch opening S5 OFF Prevents Dip Switch opening Switch no 6 RAZ and Secure Features...

Страница 8: ...nce on the Dip Switch detector button 2 The LED above the button remains lighted You have 10 seconds to press one of the buttons on a pre programmed remote control with Dip Switch 3 The remote has been saved when the LED begins to flash 4 To exit detection mode Press once on the push button or wait for the LED to switch off D OPENING WITH DIP SWITCH CODES From then on each remote control with a Di...

Страница 9: ...onnected to a pushbutton type input to the devices that need controlling If these devices do not have an input of this kind use an intermediate power relay of the correct capacity Notes If the range of the remote controls is too low the 07 0106 EN receiver fails to detect a signal position the aerial NOT PROVIDED in different locations to find the best one if possible in an open space away from me...

Страница 10: ...ied radio standard EN 300 220 3 2000 applied B CABLING Please be sure to follow the recommendations given on the cabling and connection diagrams especially concerning the distance and diameter of wiring between the HF receiver and the control unit of GSM 3G unit If this is not the case no warranty will be given C END OF LIFE PRODUCT RECYCLING The receiver and its accessories must not be disposed o...

Отзывы: