background image

7

TEMPORARY CHANGE TO LASER CUT MODE

In the laser cut mode cuts are made from flat edge to flat
edge without the normal inbetween cut points.  From the
ready prompt push the 

C.F.

 key three times, the display will

read normal cut mode.  Push the (

-

) key to toggle to the laser cut mode and back to the normal

cut mode.

HALF DEPTH MODE

4. Press 

 four times.  The ITL950C will now display  

HALF-DEPTH = NO 

This is the normal

mode.  Push 

  

to switch to the half depth mode and all cuts will be made half way to the next

depth.  When cutting the key the second line will read < 1/2 Depth = on >.

PLUNGE CUT MODE

5. Press 

 

five times. The ITL950C will now display 

PLUNGE = NONE

 (Normal cut method)

PLUNGE = ALL

 (for keys that require straight in and out movement of the cutter) Safety deposit or

flat steel. 

PLUNGE = FIRST

 (for keys that require a vertical entry in the first position to avoid cutting

the key shoulder). Press 

 key to toggle to required function, press 

 to return to 

READY.

CHANGING CUT RATE

6. The cut rate is a number from 1 through 4 that defines how fast a blank is fed into the cutter. 1 is the

fastest rate and should work for most blanks. However if the cutter becomes dull or thick—blanks are

used you may need to select a slower speed. To select a cut rate of 3, proceed as follows. Press the

 

key 6 times. The display will now read 

CUT FEED RATE (current rate) 

press 

 and 

,

 the display will now read 

CUT FEED RATE 3.

 Press 

 

to return to 

READY.

BYPASS HOME MODE

7.

Press 

 

seven times.  The ITL950C will now display 

BYPASS HOME = NO 

This will

reset the space calibration after every cut.  Press the 

 

key to toggle to 

BYPASS HOME =

YES

 this will temporarily turn off the space calibration.  This can be used for impressioning locks

faster.  Press 

 

to return to

 READY.

UNITS (METRIC OR INCHES)

8.

Press 

 

eight times. The ITL950C will now display 

UNITS (INCHES OR METRIC).

Press 

 

key to toggle.

CUSTOM EDIT MODE

           Custom default entries using the

 

 key remain in memory when the machine is reset or

turned off.

Содержание 950C

Страница 1: ...ITL 950C THE ITL 950C COMPUTER KEY MACHINE Operations Manual QRS BCD KLM ...

Страница 2: ...e 9 IV CREATING A CUSTOM ID TABLE Selecting ID To Be Created 10 Enabling and Disabling Pause 10 Setting Tip Type 10 Table of reference points 10 Selecting a Flat 10 Selecting Insert Number 10 Enabling an Extended Table 11 Setting Maximum Space 11 Setting Maximum Depth 11 Setting Minimum Depth 11 Setting Values In Space Table 12 Setting Values In Depth Table 12 Special cutting instructions 13 VI SE...

Страница 3: ...r 1 8 H P Cutter Speed 1600 R P M Motor Bearing Type Sealed Roller Bearing Standard Codes UP TO 800 Custom Codes 160 User Modified User Definable Flats 10 with range of 0 001 to 0 140 Display Format 4 Line 20 Character Alpha Numeric Micro Power LCD Keyboard Type 20 Key Sealed Membrane Computer Interface RS232C 75 9600 Baud Parallel IBM compatible Repeatable Accuracy 0 002 Weight 48 Lbs Packaged ...

Страница 4: ...ndicate a right cut angle Displays selected amount of depth correction flat number units plunge mode and cut feed rate Starts cutting operation If the table is paused this resumes cutting after changing angles or space position of cutter Corrects number entries and aborts functions Resets the machine same as turning power on Also aborts a cutting operation Entry keys for ID S Codes Etc Used to ent...

Страница 5: ...tions CUTTING A DIRECT ENTRY CODE key cuts To load a new direct entry code press the desired cuts then press The ITL950C will display the desired cuts indicating it has accepted the cuts CUTTING A KEY In this example we will use MFG number 167 WEISER and cuts 42312 1 Select Manufacturer 167 by pressing followed by The ITL950C will display MANUFACTURER 167 INSERT 2 FLAT 8 indicating the new ID is a...

Страница 6: ...CE AS IT WILL DAMAGE THE CUTTER TO CHECK CALIBRATIONS First select MFG 391 this is Schlage Next place insert 2 in the vice jaw and slide a blank onto it Push the key along the top of the insert until the bottom shoulder comes up hard against the insert Check the right hand side of the vice Make sure the insert is tight against the stop screw Tighten the vise and press When the cut is finished remo...

Страница 7: ...pth 5 Plunge mode cut entry method 6 Cut feed rate speed that plunge method uses 7 Bypass home 8 Units inches or metric It should be noted if the machine is turned off the key pressed or the manufacture I D changed all key functions revert to the default settings SETTING TEMPORARY DEPTH CORRECTION 1 The correction function affects the depth of all cuts Anegative correction factor makes cuts deeper...

Страница 8: ...lder Press key to toggle to required function press to return to READY CHANGING CUT RATE 6 The cut rate is a number from 1 through 4 that defines how fast a blank is fed into the cutter 1 is the fastest rate and should work for most blanks However if the cutter becomes dull or thick blanks are used you may need to select a slower speed To select a cut rate of 3 proceed as follows Press the key 6 t...

Страница 9: ...ey three times and the display will read UNITS INCHES To read the display in metric press the key Press the key twice and follow display instructions SETTING DEFAULT CUT RATE The default cut rate is a number from 1 through 4 that defines how fast the blank is fed into the cutter 1 is the fastest rate and should work for most blanks however if the cutter becomes dull or thick blanks are used you ma...

Страница 10: ... step through all the 10 flats To change a flat enter the desired flat width and press For a table of flat numbers and widths refer to the table below FLAT WIDTH TABLE FLAT WIDTH EQUIVALENT CUTTER 1 0 014 INCH CW1012 2 0 024 INCH 37MC USE FOR ASSA 3 0 044 INCH CW1011 4 0 048 INCH 14MC 5 0 036 INCH 4711 6 0 032 INCH Assa 7 0 070 INCH 20MC 8 0 090 INCH CC100 9 INCH USER DEFINED WIDTH 10 INCH USER DE...

Страница 11: ...OFFSET RANGE OF SPACES NOTES 0 0 000 INCHES 0 001 1 350 INCHES SHOULDER REFERENCE 1 1 025 INCHES 0 000 0 749 INCHES SAFETY DEPOSIT KEYS 2 1 150 INCHES 0 000 1 149 INCHES USE INSERTS 1A 1B 1S 3 1 350 INCHES 0 000 1 349 INCHES REFERENCE FROM RIGHT VISE EDGE SELECTING A FLAT Press the lTL950C now displays FLAT NUMBER The flat determines how wide the bottom of each cut will be Note flat 1 produces the...

Страница 12: ...his case 804 as with any other custom ID however you need enter only spaces 1 and 2 Space 1 would be the 11th space in an extended ID and space 2 would the 12th space MAXIMUM SPACE Press the ITL950C now displays MAXIMUM SPACE The range is 1 to 10 To select a maximum space number of 7 press followed by The display will now show MAXIMUM SPACE 7 The maximum space number is used to verify correct tabl...

Страница 13: ...ry and to continue to DEPTH 1 0000 Now continue to make entries until all depth entries are completed The ITL950C will automatically return to EDIT Press key the ITL950C will display PUSH TO UPDATE TABLE CLEAR TO CANCEL Press key to set entries Now follow display commands to return to default To sum up be sure your entries are all correct and should your new code fail to work as expected DON T PAN...

Страница 14: ...the cutter motor will start wait until the cutter rests on the bottom of the cut 5 Turn the handle counter clockwise to complete the remainder of the cuts in a regular fashion Non Biaxial Medeco MFG 298 299 302 Note CW1012 cutter should be installed for Medeco 1 flat should be set to 14 thousands To cut a key with a code 1 LEFT 2 CENTER 2 RIGHT 1 CENTER 2 LEFT push the then Note the center cuts ar...

Страница 15: ...INVALID MFG ID The ID entered is incorrect the valid range is 0 through 960 0 is a special case used to load from the serial port INVALID SPACE The space number or value entered is incorrect See EDITING A CUSTOM ID TABLE for more information CODE TOO LONG The code entered is too long SPACE ERROR 10 Space calibration has failed Check for obstruction May also be a machine failure DEPTH ERROR 11 Dept...

Страница 16: ...through 3 RANGE IS 0 TO 3 INVALID FLAT WIDTH The fiat number selected is invalid The range is 1 through 10 RANGE IS 1 TO 10 INVALID DEPTH The depth entered is invalid The range is 110 TO 465 RANGE IS 110 TO 465 INVALID SPACE VALUE The space entered is out of range The range is 1 to 10 RANGE IS 1 TO 10 BAD TABLE ENTRY The table being loaded has invalid entries If the entry is a custom ID then reche...

Страница 17: ...lay will read MOVE VICE S BKQDMS The vise direction indicator will be flashing turn the space handle clockwise untill the bars disapear the numbers count down to 0000 and the display reads CUT TO CONTINUE 8 Press cutter motor will start and the first cut will be made When the cutter motor stops follow the direction indicator counterclockwise to the second cut When the display reads 0000 and CUT TO...

Страница 18: ...ts to Remote Send Masterkey Report to computer for Printing Send Hardware Report to computer for Printing Send Keying Chart to computer for Printing Restore System Defaults CREATING A 950C MASTER KEYING CHART Rotate sequence 12345 Toggle MK or GMK GMK ______ MK 2 Step control 22222 MK 1 Number of change keys MK 2 Number of change keys Change System Variables Go to page 13 for instructions on cutti...

Страница 19: ...18 Need more help Our technical support team is committed to helping you Email Us techsupport intralocktools com or call toll free at 1 888 264 6627 Check our other ITL products www intralocktools com ...

Отзывы: